Local INR calibration of the Owren type prothrombin assay greatly improves the intra- and interlaboratory variation
Show others and affiliations
2004 (English)In: Thrombosis and Haemostasis, ISSN 0340-6245, E-ISSN 2567-689X, Vol. 91, no 2, p. 300-307Article in journal (Refereed) Published
Abstract [en]

In 1999, a simplified procedure for calibration of the Owren prothrombin time (Owren PT) assay was introduced by a working group of the organisation for national quality assurance in laboratory medicine in Sweden. The new protocol allowed local calibration by means of only two lyophilised national plasma calibrators and expression of results as an international normalized ratio (INR). This is our report of a three-year follow-up involving the analysis of data from all laboratories, in hospitals (n=88 in 2002) and primary health care units (n=246 in 2002) that perform the Owren PT assay in Sweden. The interlaboratory variation was significantly improved after the introduction of the new calibration procedure. For the larger hospital-based laboratories, the mean coefficient of variation (CV) was reduced from 7.9% to 5.2% (p<0.0001) when analysing test materials with INR range 2-4. In the higher INR range (>4), the CV was reduced even further, from 10.4% to 6.8% (p<0.0001). The corresponding results from smaller laboratories in the primary health care units showed a similar decrease in CV from 8.2% to 5.7% in the INR range 2-4 (p<0.0001). At the INR range >4, the CV was reduced from 9.5% to 7.8%. The intralaboratory variation was also improved for both types of laboratory categories. This study shows an improved precision, with CV less than 6% at the therapeutic INR range, for both hospital-based laboratories and smaller laboratories in the primary health care system. The results indicate that the Owren PT assay is well suited for local INR calibration employing only two calibrant plasmas in a simplified procedure.

Place, publisher, year, edition, pages
2004. Vol. 91, no 2, p. 300-307
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-23581Local ID: 3065OAI: oai:DiVA.org:liu-23581DiVA, id: diva2:243896
Available from: 2009-10-07 Created: 2009-10-07 Last updated: 2023-08-28

Open Access in DiVA

No full text in DiVA

Authority records

Lindahl, Tomas

Search in DiVA

By author/editor
Lindahl, Tomas
By organisation
Faculty of Health SciencesDivision of clinical chemistryDepartment of Clinical Chemistry
In the same journal
Thrombosis and Haemostasis
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 191 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf