liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
CO2 emission evaluation of energy conserving measures in buildings connected to a district heating system - Case study of a multi-dwelling building in Sweden
Gavle Energi AB, Sweden; University of Gavle, Sweden.
Dalarna University, Sweden.
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska fakulteten.
University of Gavle, Sweden.
2016 (engelsk)Inngår i: Energy, ISSN 0360-5442, E-ISSN 1873-6785, Vol. 111, s. 341-350Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

When taking action to fulfill the directives from the European Union, energy conserving measures will be implemented in the building sector. If buildings are connected to district heating systems, a reduced heat demand will influence the electricity production if the reduced heat demand is covered by combined heat and power plants. This study analyze five different energy conserving measures in a multi-dwelling building regarding how they affect the marginal production units in the district heating system in Gavle, Sweden. For CO2 emission evaluations, two different combinations of heat and electricity conserving measures are compared to an installation of an exhaust air heat pump. The different energy conserving measures affect the district heating system in different ways. The results show that installing an exhaust air heat pump affects the use/production of electricity in the district heating system most and electricity conserving measures result in reduced use of electricity in the building, reduced use of electricity for production of heat in the district heating system and an increase of electricity production. The conclusion is that electricity use in the building is the most important factor to consider when energy conserving measures are introduced in buildings within the district heating system in Gavle. (C) 2016 Elsevier Ltd. All rights reserved.

sted, utgiver, år, opplag, sider
PERGAMON-ELSEVIER SCIENCE LTD , 2016. Vol. 111, s. 341-350
Emneord [en]
District heating system; Energy efficiency; Refurbishment; Simulation; Greenhouse gases
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-132479DOI: 10.1016/j.energy.2016.05.002ISI: 000384776900029OAI: oai:DiVA.org:liu-132479DiVA, id: diva2:1046266
Merknad

Funding Agencies|industrial post-graduate school Reesbe; Knowledge Foundation (KK-stiftelsen)

Tilgjengelig fra: 2016-11-13 Laget: 2016-11-12 Sist oppdatert: 2017-11-29

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Trygg, Louise
Av organisasjonen
I samme tidsskrift
Energy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 55 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf