liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Radiation protection measurements with the variance-covariance method in the stray radiation fields from photon and proton therapy facilities
Swedish Radiation Safety Authority, Stockholm, Sweden.
Swedish Radiation Safety Authority, Stockholm, Sweden.
Center for Nuclear Technologies, Technical University of Denmark, Roskilde, Denmark.
The Skandion Clinic, Uppsala, Sweden.ORCID-id: 0000-0001-8171-2541
Vise andre og tillknytning
2018 (engelsk)Inngår i: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 180, nr 1-4, s. 338-341Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The microdosimetric variance–covariance method was used to study the stray radiation fields from the photon therapy facility at the Technical University of Denmark and the scanned proton therapy beam at the Skandion Clinic in Uppsala, Sweden. Two TEPCs were used to determine the absorbed dose, the dose-average lineal energy, the dose-average quality factor and the dose equivalent. The neutron component measured by the detectors at the proton beam was studied through Monte Carlo simulations using the code MCNP6. In the photon beam the stray absorbed dose ranged between 0.3 and 2.4 μGy per monitor unit, and the dose equivalent between 0.4 and 9 μSv per monitor unit, depending on beam energy and measurement position. In the proton beam the stray absorbed dose ranged between 3 and 135 μGy per prescribed Gy, depending on detector position and primary proton energy.

sted, utgiver, år, opplag, sider
Oxford University Press, 2018. Vol. 180, nr 1-4, s. 338-341
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-144119DOI: 10.1093/rpd/ncx194ISI: 000440983000071PubMedID: 29036696OAI: oai:DiVA.org:liu-144119DiVA, id: diva2:1171293
Tilgjengelig fra: 2018-01-07 Laget: 2018-01-07 Sist oppdatert: 2018-09-07bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Dasu, AlexandruArdenfors, Oscar
I samme tidsskrift
Radiation Protection Dosimetry

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 83 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf