Using force-displacement relations to obtain actuation parameters from artificial muscles
Univ Wollongong, Australia.
US Army, MD 20783 USA; Cornell Univ, NY 14850 USA.
Linköpings universitet, Institutionen för fysik, kemi och biologi, Sensor- och aktuatorsystem. Linköpings universitet, Tekniska fakulteten.
Univ Wollongong, Australia.
Vise andre og tillknytning
2019 (engelsk)Inngår i: Sensors and Actuators A-Physical, ISSN 0924-4247, E-ISSN 1873-3069, Vol. 290, s. 90-96Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Many different test methods are currently used to characterise the output of artificial muscle materials but few studies report the full range of possible force and displacements that can be generated by a given material when activated with a given input stimulus but when operated against different external loads. The measurement of the loading and unloading force extension curves in tension in both the un-activated and activated states is investigated as a means for efficiently characterising the full range of outputs for three different types of artificial muscles: pneumatically operated braided muscle and thermally operated shape memory alloy spring and twisted / coiled polymer fiber. A graphical method of analysis was applied whereby the force-extension curves obtained before and after actuator activation were plotted on the same axes. By overlaying the external loading conditions, the graphical method provided the equilibrium starting and finishing forces and displacements and successfully predicted the isotonic strokes, isometric forces and combined force and displacement generated when the actuator was operated against an external spring. Complications in the interpretation of the force-stroke curves were encountered as all three artificial muscles displayed a degree of loading-unloading hysteresis and non-ideal mechanical behavior. (C) 2019 Elsevier B.V. All rights reserved.

sted, utgiver, år, opplag, sider
ELSEVIER SCIENCE SA , 2019. Vol. 290, s. 90-96
Emneord [en]
Artificial muscle; Stroke; Force; Stiffness; Test method
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-157539DOI: 10.1016/j.sna.2019.03.012ISI: 000466256000012OAI: oai:DiVA.org:liu-157539DiVA, id: diva2:1328677
Tilgjengelig fra: 2019-06-22 Laget: 2019-06-22 Sist oppdatert: 2019-06-22

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Aziz, Shazed
Av organisasjonen
I samme tidsskrift
Sensors and Actuators A-Physical

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 4 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf