Quantitative Assessment and Repeatability of Chlorine in Exhaled Breath Condensate: Comparison of Two Types of Condensators
Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
Linköpings universitet, Institutionen för medicin och hälsa, Anestesiologi med intensivvård. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Anestesi- och operationscentrum, Intensivvårdskliniken US.
Linköpings universitet, Institutionen för tema, Tema vatten i natur och samhälle. Linköpings universitet, Filosofiska fakulteten.
Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
2005 (engelsk)Inngår i: Respiration, ISSN 0025-7931, E-ISSN 1423-0356, Vol. 72, nr 5, s. 529-536Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Airway condition is presumably reflected in epithelial lining fluid (ELF). Exhaled breath condensate (EBC) has been used as a surrogate marker of the composition of ELF.

Objectives: This study aimed at assessing the technical repeatability of chlorine measurements in EBC and comparing two separate condensators (Ecoscreen® and R Tube) regarding recovery and repeatability. Furthermore, the association between condensate recoveries and variations in the airway status were scrutinized.

Methods: EBC was collected using two condensators from 10 healthy volunteers. In addition, 13 asthmatic patients produced EBC with or without an added resistance of 5 cm H2O (Res5), applied to the outflow tract of Ecoscreen. All tests were done in random order. Chlorine levels (analyzed by a coulometric technique) in EBC served as a tool for investigation.

Results: Chlorine was measurable in all samples. The coefficient of repeatability of chlorine measurements was <10%. Chlorine levels were higher in EBC obtained from R Tube (p < 0.001), and differences in recoveries and variability in chlorine levels were presumably related to technical differences in the condensators and not to the repeatability of chlorine measurements per se. Air-flow-dependent chlorine levels were obtained from healthy volunteers. Application of Res5, recruiting additional alveoli, resulted in increased recovery of the EBC volume, but not of chlorine, from those that had the most pronounced airway obstruction (p = 0.05).

Conclusion: We conclude that by employing a sensitive analysis technique, chlorine is repeatedly measurable in EBC. We suggest that the bulk of chlorine in EBC originates from large airways and not from the alveolar area. Both condensators were comparable regarding repeatability but differed regarding chlorine recover

sted, utgiver, år, opplag, sider
2005. Vol. 72, nr 5, s. 529-536
Emneord [en]
Asthma, Chlorine, Exhaled breath condensate, Repeatability, Volunteers
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-16289DOI: 10.1159/000087679OAI: oai:DiVA.org:liu-16289DiVA, id: diva2:133627
Tilgjengelig fra: 2009-01-13 Laget: 2009-01-13 Sist oppdatert: 2017-12-14bibliografisk kontrollert
Inngår i avhandling
1. Exhaled Breath Condensate in Obstructive Lung Diseases: A Methodological study
Åpne denne publikasjonen i ny fane eller vindu >>Exhaled Breath Condensate in Obstructive Lung Diseases: A Methodological study
2009 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Asthma and chronic obstructive pulmonary disease (COPD) are two common inflammatory airway diseases characterized by airway inflammation and mucus hypersecretion. Prediction of the outcome of these diseases may not be performed and the need for non-invasive diagnostic tools capable of identifying inflammation in asthma and COPD becomes therefore obvious. Validation, sensitivity and specificity of most non-invasive methods to detect and monitor inflammatory responses in airways are poor and there is a great need to identify and standardize less invasive, or non-invasive methods for investigation of airway inflammation.

Epithelial lining fluid (ELF) covers the airway surface and contains soluble and insoluble inflammatory cell products and plasma proteins originating and passively transferred from the underlying tissue. Airborne aerosol particles containing ELF saturated with water may be recovered in exhaled air by allowing the air to pass a cold surface, creating exhaled breath condensate (EBC). EBC may then be analysed for various components of interest.

The aims of this thesis were (1) to explore whether a certain profile of inflammatory cell markers in EBC, saliva or serum may be identified in patients with allergic asthma or COPD, (2) to evaluate the efficacy and reproducibility of a measurable marker in EBC using either of the two condensers ECoScreen or RTube and (3) to evaluate the value of chlorine concentrations in EBC as well as reproducibility of assessments of certain compounds in EBC.

Material and methods: Thirty-six patients with asthma, 49 smokers or ex-smokers and 25 healthy volunteers participated in three clinical studies. In addition, efficacy, reproducibility and comparison of the two condensers were studied in an ex vivo set up using aerosols of solutions of saline, myeloperoxidase (MPO) or human neutrophil lipocalin (HNL). Aerosol boluses were transferred by means of a servo ventilator to either of the two condensers. Concentrations of chlorine (presumed to be a marker of mucous secretion) in EBC or saliva were analyzed by means of a sensitive coulometric technique (AOX). The inflammatory cell markers histamine, MPO, HNL, lysozyme, cysteinyl-leukotrienes (CysLT) and eosinophil cationic protein (ECP) were analysed in EBC, saliva and/or serum by means of ELISA, RIA, EIA or immunochemical fluorescence methods, respectively. Lung function tests, including diffusion capacity were measured by standard techniques according to clinical routines.

Results and Conclusions: Chlorine measurements served as the main tool in our tests and intra-assay variability <10% was recorded. However, flow dependency, temperature dependency, substance dependency and concentration dependency characterized yields of EBC. Despite acceptable analytical precision, low concentration levels of inflammation markers, biological variability and occasionally contamination with saliva mean that the feasibility of the EBC method is limited. Despite biological variability, concentrations of chlorine in EBC were significantly higher during than after a mild pollen season, suggesting that chlorine concentrations in EBC are a sensitive marker of allergic airway inflammation. A vast number of confounding factors made interpretations of EBC data obtained from COPD and non-COPD patients difficult and traditional diagnostic tools, such as diffusion capacity (DLCO) and serum lysozyme appeared to best discriminate between COPD and non-COPD.

sted, utgiver, år, opplag, sider
Linköping: Linköping University Electronic Press, 2009. s. 72
Serie
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1091
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-16294 (URN)9789173937269 (ISBN)
Disputas
2009-02-06, Elsa Brännströmssalen, Campus US, Linköpings Universitet, Linköping, 13:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2009-01-13 Laget: 2009-01-13 Sist oppdatert: 2017-12-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstLink to the Ph.D. Thesis

Personposter BETA

Davidsson, AnetteNaidu-Sjöswärd, KerstinLundman, LenaSchmekel, Birgitta

Søk i DiVA

Av forfatter/redaktør
Davidsson, AnetteNaidu-Sjöswärd, KerstinLundman, LenaSchmekel, Birgitta
Av organisasjonen
I samme tidsskrift
Respiration

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 360 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf