Cutaneous bioengineering instrumentation standardization: the Tissue Viability Imager
Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk instrumentteknik. Linköpings universitet, Tekniska högskolan.
University of California.
University of California.
Vise andre og tillknytning
2009 (engelsk)Inngår i: Skin research and technology, ISSN 0909-752X, E-ISSN 1600-0846, Vol. 15, nr 1, s. 6-13Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Tissue Viability Imaging (TiVi) is a new bioengineering technology intended for remote two-dimensional mapping of skin red blood cell concentration (RBCconc). Before use in the laboratory, work-site and dermatology clinic, critical performance parameters of this emerging technology require careful evaluation.

To assess short- and long-term stability, image uniformity, distance and image size dependence, ambient light and curvature influence in a production batch of Tissue Viability Imagers.

Four Tissue Viability Imagers from the same production batch were evaluated at two laboratories (one industrial and one dermatological) with respect to critical parameter performance.

The average systematic drift in sensitivity over time was 0.27% and < 1.02% for all four units tested. Difference in sensitivity between units was limited to 4.1% and was due to offset rather than gain deviation. Spatial variation in image uniformity was below 3.08% and 1.93% in the corners and centre of an individual image, respectively. This spatial variation could be further reduced to 0.25% and 0.13%, respectively by image normalization. Ambient light from a 40 W bulb or a 11 W fluorescent light source at a distance of 50-60 cm above the object, reduced the recorded values by about 10%, while the camera to object distance and image size had no detectable influence on sensitivity. Curved objects, such as human forearm, demonstrated an edge effect limited to below 10%.

The critical TiVi performance parameters evaluated proved stable in relation to expected variations in skin RBCconc over time. Calibration by way of a two-point method may reduce differences in sensitivity between instruments to further facilitate inter-laboratory comparison of results.

sted, utgiver, år, opplag, sider
2009. Vol. 15, nr 1, s. 6-13
Emneord [en]
Tissue Viability Imaging, skin red blood cell concentration, spectroscopy, instrument performance, skin bioengineering
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-16611DOI: 10.1111/j.1600-0846.2008.00330.xOAI: oai:DiVA.org:liu-16611DiVA, id: diva2:159517
Tilgjengelig fra: 2009-02-07 Laget: 2009-02-06 Sist oppdatert: 2017-12-14

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Nilsson, Gert

Søk i DiVA

Av forfatter/redaktør
Nilsson, Gert
Av organisasjonen
I samme tidsskrift
Skin research and technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 528 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf