liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
CE Article: Transfer Rate of Pathogens Through In Vitro Contaminated Venous Port Membranes Varies With Species, Concentration, and Injection Technique
Department of Anaesthesia and Intensive Care Medicine, Ryhov County Hospital, Jönköping and Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
Microbiology Laboratory, Division of Medical Diagnosis, Jönköping County, Sweden.
Department of Anaesthesia and Intensive Care Medicine, Ryhov County Hospital, Sweden.
Department of Infectious Diseases and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden.
Vise andre og tillknytning
2019 (engelsk)Inngår i: Journal of the Association for Vascular Access, ISSN 1552-8855, Vol. 24, nr 3, s. 16-22Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Introduction: Reliable venous access is a cornerstone in delivery of cytotoxic drugs, and subcutaneous venous ports (SVPs) are commonly used. Pocket infection is a major complication that can lead to SVP removal and treatment delay. Consensus is lacking whether a suspected port infection is a contraindication to continued use. Our aim was to examine the extent of pathogen transfer into a SVP by puncturing an in vitro contaminated injection membrane and to evaluate techniques to reduce this transmission.

Method: Four pathogens were applied to SVP membranes in concentrations mimicking clinical infection, and the membranes punctured with or without flow through the needle. The port was then flushed with saline, and samples from the outlet were analyzed.

Results: Microorganisms were transported into the SVP when puncturing the contaminated membrane. The number of microorganisms transferred was related to the concentration of microorganisms on the membrane and varied with species. Flow through the needle during insertion reduced the number of bacteria transported through the SVP membrane.

Discussion: Our results indicate that a limited number of pathogens are likely to be introduced into the SVP chamber when puncturing a contaminated membrane. The number of bacteria transferred could be reduced by applying flow during puncture.

sted, utgiver, år, opplag, sider
2019. Vol. 24, nr 3, s. 16-22
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-190067DOI: 10.2309/j.java.2019.003.002OAI: oai:DiVA.org:liu-190067DiVA, id: diva2:1712102
Tilgjengelig fra: 2022-11-20 Laget: 2022-11-20 Sist oppdatert: 2022-12-08

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 14 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf