Shaping X-ray spectra with filters in X-ray diagnostics
Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen. Linköpings universitet, Hälsouniversitetet.ORCID-id: 0000-0003-3352-8330
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.ORCID-id: 0000-0003-0209-498X
1994 (engelsk)Inngår i: Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444, Vol. 32, nr 4, s. 384-390Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The influence on image contrast, tube load and patient mean absorbed dose of different ways of shaping diagnostic X-ray spectra by placing filters in the beam is derived for two radiographic models (abdominal screen-film radiography and intra-oral, dental radiography) using a computational model. The filters are compared at either equal tube load (keeping tube potential constant) or equal contrast (adjusting the tube potential with the different filters), but always at equal energy imparted per unit area to the image receptor. Compared at equal tube load and relative to standard aluminium filtration, reductions in the mean absorbed dose in the patient of 15–25% can be achieved using filters of Cu, Ti, W and Au (increasing the tube load by 30–40% compared with standard aluminium filtration). However, contrast is also reduced by 7%. Compared at equal contrast, the dose reductions are smaller, about 10%. Filters of copper are generally recommended, as are filters of aluminium. The use of bandpass filters (K-edge filters) should be restricted to examinations where the need for substantial variation in tube potential from patient to patient is small. The benefit of using thicker filters than those commonly used today (increasing tube load by factors of 1.4–2.0 compared with no added filter) is small as the dose reduction is most rapid for small initial values of added filters, and the increase in tube load increases steadily with increasing filter thickness.

sted, utgiver, år, opplag, sider
1994. Vol. 32, nr 4, s. 384-390
Emneord [en]
Absorbed dose - Contrast - Filter - X-ray spectra
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-20943DOI: 10.1007/BF02524689OAI: oai:DiVA.org:liu-20943DiVA, id: diva2:236856
Tilgjengelig fra: 2009-09-25 Laget: 2009-09-25 Sist oppdatert: 2017-12-13

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Sandborg, MichaelCarlsson, C. A.Alm Carlsson, Gudrun

Søk i DiVA

Av forfatter/redaktør
Sandborg, MichaelCarlsson, C. A.Alm Carlsson, Gudrun
Av organisasjonen
I samme tidsskrift
Medical and Biological Engineering and Computing

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 65 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf