Automatic tube-current modulation in CT - A comparison between different solutions
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Kirurgiska kliniken i Östergötland med verksamhet i Linköping, Norrköping och Motala. Linköpings universitet, Tekniska högskolan.
2005 (engelsk)Inngår i: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 114, nr 1-3, s. 308-312Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In this study, tube-current modulation systems on two different CT equipments have been evaluated: Care Dose from Siemens and Auto mA from GE Medical Systems. Care Dose modulates the tube current in the xy-plane during rotation whereas Auto mA modulates the tube current in the z-direction. xy-Plane modulation was investigated by using an elliptic Poly-methylmethacrylate phantom and a CTDI-ion chamber. To investigate modulation in the z-direction, an anthropomorphic dosimetry phantom (Atom) was used. Tests performed with and without tube-current modulation were compared with respect to absorbed dose and image quality. In the anthropomorphic phantom measurements, the dose savings were 15% using Care Dose and the photon starvation artefacts were negligible. Using Auto mA the absorbed dose depends on the chosen noise level. Image noise becomes more constant throughout the patient but photon starvation artefacts remain. We conclude that the two tube-current modulation techniques show different dose advantages and image quality artefacts. © The Author 2005. Published by Oxford University Press. All rights reserved.

sted, utgiver, år, opplag, sider
2005. Vol. 114, nr 1-3, s. 308-312
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-28735DOI: 10.1093/rpd/nch501Lokal ID: 13907OAI: oai:DiVA.org:liu-28735DiVA, id: diva2:249547
Tilgjengelig fra: 2009-10-09 Laget: 2009-10-09 Sist oppdatert: 2017-12-13

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Nilsson, Jonas

Søk i DiVA

Av forfatter/redaktør
Nilsson, Jonas
Av organisasjonen
I samme tidsskrift
Radiation Protection Dosimetry

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 68 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf