Age and gender do not influence the ability to detect respiration by photoplethysmography
Linköpings universitet, Institutionen för medicin och hälsa, Anestesiologi med intensivvård. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för medicin och hälsa, Anestesiologi med intensivvård. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Hälsouniversitetet.
Vise andre og tillknytning
2006 (engelsk)Inngår i: Journal of clinical monitoring and computing, ISSN 1387-1307, E-ISSN 1573-2614, Vol. 20, nr 6, s. 431-436Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Objective  The non-invasive technique photopl- ethysmography (PPG) can detect changes in blood volume and perfusion in a tissue. Respiration causes variations in the peripheral circulation, making it possible to monitor breaths using an optical sensor attached to the skin. The respiratory-synchronous part of the PPG signal (PPGr) has been used to monitor respiration during anaesthesia, and in postoperative and neonatal care. Studies addressing possible differences in PPGr signal characteristics depending on gender or age are lacking.

Methods  We studied three groups of 16 healthy subjects each during normal breathing; young males, old males and young females, and calculated the concordance between PPGr, derived from a reflection mode PPG sensor on the forearm, and a reference CO2 signal. The concordance was quantified by using a squared coherence analysis. Time delay between the two signals was calculated. In this process, we compared three different methods for calculating time delay.

Results  Coherence values ≥0.92 were seen for all three groups without any significant differences depending on age or gender (p = 0.67). Comparison between the three different methods for calculating time delay showed a correlation r = 0.93.

Conclusions  These results demonstrate clinically important information implying the possibility to register qualitative PPGr signals for respiration monitoring, regardless of age and gender.

sted, utgiver, år, opplag, sider
2006. Vol. 20, nr 6, s. 431-436
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-37154DOI: 10.1007/s10877-006-9050-zLokal ID: 33808OAI: oai:DiVA.org:liu-37154DiVA, id: diva2:258003
Tilgjengelig fra: 2009-10-10 Laget: 2009-10-10 Sist oppdatert: 2018-03-23bibliografisk kontrollert
Inngår i avhandling
1. Respiratory monitoring using reflection mode photoplethysmography: clinical and physiological aspects
Åpne denne publikasjonen i ny fane eller vindu >>Respiratory monitoring using reflection mode photoplethysmography: clinical and physiological aspects
2005 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Photoplethysmography (PPG) is a non-invasive optical technique for monitoring variations in blood volume and blood flow in skin and other tissues. Light from a light-emitting diode is absorbed, scattered and reflected from the skin, and detected by a photodetector as a plethysmogram. The plethysmogram contains variations of different frequencies. The most clinically utilised is the pulse synchronous variation in the PPG application pulse oximetry, but there is also a respiratory rate synchronous variation (PPGt).

The aims of this work were to evaluate PPG as a clinical method for detection of breaths during anaesthesia, postoperative and intensive care, and to investigate possible circulatory factors in the physiological background of the respiratory synchronous part of the reflection mode PPG signal.

It was concluded that respiratory variations in reflection mode PPG derived from the forearm could be detected with high sensitivity and specificity. PPG, was not significantly affected by awake or anaesthetised state, though indirect signs of reduced sympathetic tone in the anaesthetic state were present, or by spontaneous or positive pressure ventilation. There were no significant differences between men and women or between young and old subjects. Circulatory pressure variations in phase with respiration were present on both the arterial and venous side and they showed the same degree of variation, as did PPG when provoking respiration. Squared coherence, cross-correlation and visual techniques for evaluating time differences were equally good.

Respiratory monitoring in the clinical setting is challenging and no golden standard exists. Methods based on airflow are mostly considered advantageous in detecting apnoea, but are less well tolerated by patients. The results indicate that PPG has a potential as a tool for monitoring respiratory rate. It is non-invasive, well tolerated and can be used for continuous monitoring.

sted, utgiver, år, opplag, sider
Linköping: Linköpings universitet, 2005. s. 70
Serie
Linköping University Medical Dissertations, ISSN 0345-0082 ; 898
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-31535 (URN)17335 (Lokal ID)91-8529-905-7 (ISBN)17335 (Arkivnummer)17335 (OAI)
Disputas
2005-05-26, Elsa Brändström-salen, Universitetssjukhuset, Linköping, 12:00 (svensk)
Opponent
Tilgjengelig fra: 2009-10-09 Laget: 2009-10-09 Sist oppdatert: 2012-09-27bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Nilsson, LenaGoscinski, TomasJohansson, AndersLindberg, Lars-GöranKalman, Sigga

Søk i DiVA

Av forfatter/redaktør
Nilsson, LenaGoscinski, TomasJohansson, AndersLindberg, Lars-GöranKalman, Sigga
Av organisasjonen
I samme tidsskrift
Journal of clinical monitoring and computing

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 418 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf