liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Detection of mild emphysema by computed tomography density measurements
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik.
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik.ORCID-id: 0000-0002-9267-2191
Vise andre og tillknytning
2005 (engelsk)Inngår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 46, nr 3, s. 237-245Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Purpose: To assess the ability of a conventional density mask method to detect mild emphysema by high- resolution computed tomography ( HRCT), to analyze factors influencing quantification of mild emphysema, and to validate a new algorithm for detection of mild emphysema. Material and Methods: Fifty- five healthy male smokers and 34 never- smokers, 61 - 62 years of age, were examined. Emphysema was evaluated visually, by the conventional density mask method, and by a new algorithm compensating for the effects of gravity and artifacts due to motion and the reconstruction algorithm. Effects of the reconstruction algorithm, slice thickness, and various threshold levels on the outcome of the density mask area were evaluated. Results: Forty- nine percent of the smokers had mild emphysema. The density mask area was higher the thinner the slice irrespective of the reconstruction algorithm and threshold level. The sharp algorithm resulted in increased density mask area. The new reconstruction algorithm could discriminate between smokers with and those without mild emphysema, whereas the density mask method could not. The diagnostic ability of the new algorithm was dependent on lung level. At about 90% specificity, sensitivity was 65 - 100% in the apical levels, but low in the rest of the lung. Conclusion: The conventional density mask method is inadequate for detecting mild emphysema, while the new algorithm improves the diagnostic ability but is nevertheless still imperfect.

sted, utgiver, år, opplag, sider
2005. Vol. 46, nr 3, s. 237-245
Emneord [en]
computed tomography, computerized quantification, emphysema, validation
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-46113DOI: 10.1080/02841850510021012OAI: oai:DiVA.org:liu-46113DiVA, id: diva2:267009
Tilgjengelig fra: 2009-10-11 Laget: 2009-10-11 Sist oppdatert: 2017-12-13

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Friman, OlaBorga, Magnus

Søk i DiVA

Av forfatter/redaktør
Friman, OlaBorga, Magnus
Av organisasjonen
I samme tidsskrift
Acta Radiologica

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 600 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf