Investigation of indoor climate and power usage in a data center
Linköpings universitet, Institutionen för konstruktions- och produktionsteknik, Energisystem. Linköpings universitet, Tekniska högskolan.
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem.
2005 (engelsk)Inngår i: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 37, nr 10, s. 1075-1083Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Thermal management of data centers is an important issue for many high technology companies. The power requirement to provide proper indoor climate in data centers is considerable. Thus, possibilities for energy savings and efficient electricity utilization are quite important. In this paper, the airflow and temperature patterns, as well as the electrical power requirement within a small data center, have been investigated. The power requirement within the data center is considerably high, due to an oversized air conditioning system. An infrared camera was used to visualize the airflow and temperature pattern, showing that cool air does not reach the upper levels of the racks, despite a very high air exchange rate. Point measurements of temperatures in a rack show that recirculation cells are present, causing accumulation of heat and improper cooling of electronic equipments. Thus, the chilled air is not distributed properly and consequently the cooling energy is not used effectively. © 2005 Elsevier B.V. All rights reserved.

sted, utgiver, år, opplag, sider
2005. Vol. 37, nr 10, s. 1075-1083
Emneord [en]
Airflow pattern, Data center, Indoor climate, IR camera, Power requirement, Thermal management, Visualization
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-50419DOI: 10.1016/j.enbuild.2004.12.014OAI: oai:DiVA.org:liu-50419DiVA, id: diva2:271315
Tilgjengelig fra: 2009-10-11 Laget: 2009-10-11 Sist oppdatert: 2017-12-12

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Karlsson, J.FredrikMoshfegh, Bahram

Søk i DiVA

Av forfatter/redaktør
Karlsson, J.FredrikMoshfegh, Bahram
Av organisasjonen
I samme tidsskrift
Energy and Buildings

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 165 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf