liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Concentration of uric acid removed during dialysis. Estimated by multi wavelength and processed ultra violet absorbance spectra
Tallinn University.
Linköpings universitet, Institutionen för medicin och hälsa, Internmedicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Njurmedicinska kliniken US.
Tallinn University.
Tallinn University.
Vise andre og tillknytning
2010 (engelsk)Inngår i: Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE, ISSN: 1557-170X, IEEE , 2010, Vol. 2010, s. 5791-5794Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

The aim of this study was to estimate the concentration of uric acid (UA) optically by using original and processed ultra violet (UV) absorbance spectra's of the spent dialysate. Also the effect of using several wavelengths for estimation was examined. Ten uremic patients from Tallinn and ten from Linkoping, during 30+40 hemodialysis treatments, were followed at the Departments of Dialysis and Nephrology at North-Estonian Medical Centre and at Linkoping University Hospital. The dialysate samples were taken and analyzed by means of UA concentration at the chemical laboratory and with a doublebeam spectrophotometer. From the calibration set of material three models for original and three for Is' derivate of UV absorbance were created. These models were tested on validation set of material and concentrations of UA from the different methods were compared regarding mean values and SD. It was found that the concentration of UA can be estimated by UV absorbance method whereby using processed UV absorbance spectra and absorbance values from several wavelengths gives better and more accurate results.

sted, utgiver, år, opplag, sider
IEEE , 2010. Vol. 2010, s. 5791-5794
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-66391DOI: 10.1109/IEMBS.2010.5627831PubMedID: 21097101ISBN: 978-1-4244-4123-5 (tryckt)OAI: oai:DiVA.org:liu-66391DiVA, id: diva2:403685
Konferanse
Engineering in Medicine and Biology Society (EMBC), 2010
Tilgjengelig fra: 2011-03-14 Laget: 2011-03-14 Sist oppdatert: 2011-12-08

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Uhlin, Fredrik

Søk i DiVA

Av forfatter/redaktør
Uhlin, Fredrik
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
isbn
urn-nbn

Altmetric

doi
pubmed
isbn
urn-nbn
Totalt: 116 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf