liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Are cutaneous microdialysis cytokine findings supported by end-point biopsy immunohistochemistry findings?
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Dermatologi och venerologi. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Dermatologi och venerologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Hudkliniken i Östergötland.
2010 (engelsk)Inngår i: AAPS Journal, ISSN 1550-7416, E-ISSN 1550-7416, Vol. 12, nr 4, s. 741-749Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Insertion of a cutaneous microdialysis catheter into normal dermis has been shown to induce the production of IL1b, IL6 and IL8 in an innate response to minimal trauma. In the present study, skin biopsy for immunohistochemistry has been performed at the site of the microdialysis catheter to compare the findings with that of the microdialysis findings 24 h after insertion. Of the three named cytokines, concordance between the two investigated technologies was highest for IL8 (100%) followed by IL6 (70%) and IL1b (50%). For seven other pro-inflammatory and T cell-relevant cytokines studied, concordance ranged between 50% and 80%. The total number of positive (microdialysis or immunofluorescence) findings was similar between the two methodologies. Technical and biological phenomenon can explain the differences. We conclude that both methodologies illustrate important features of tissue biology and that a combination of the two methods in clinical research can provide the chronology of soluble mediator participation and the more classic, but also more invasive, biopsy-based methodology at a point which constitutes the end of the observation period. We conclude further that at the 24-h time period here studied, microdialysis catheters are still functional and thus capable of producing relevant data which can be corroborated and extended by the “end point biopsy”.

sted, utgiver, år, opplag, sider
2010. Vol. 12, nr 4, s. 741-749
Emneord [en]
cutaneous microdialysis, cytokines, human, immunostaining, innate
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-66928DOI: 10.1208/s12248-010-9235-8ISI: 000288426100028OAI: oai:DiVA.org:liu-66928DiVA, id: diva2:405379
Tilgjengelig fra: 2011-03-22 Laget: 2011-03-22 Sist oppdatert: 2017-12-11

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Sjögren, FlorenceAnderson, Chris D

Søk i DiVA

Av forfatter/redaktør
Sjögren, FlorenceAnderson, Chris D
Av organisasjonen
I samme tidsskrift
AAPS Journal

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 97 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf