liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Innovative starting procedure of Siemens SGT-600 in cold climate conditions
Siemens Industrial Turbomachinery AB, Finspång.
Siemens Industrial Turbomachinery AB, Finspång.
Siemens Industrial Turbomachinery AB, Finspång.
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Konstruktionsmaterial. Linköpings universitet, Tekniska högskolan.ORCID-id: 0000-0002-8304-0221
2011 (engelsk)Inngår i: ASME 2011 Turbo Expo:Turbine Technical Conference and Exposition: Volume 4: Cycle Innovations; Fans and Blowers; Industrial and Cogeneration; Manufacturing Materials and Metallurgy; Marine; Oil and Gas Applications, The American Society of Mechanical Engineers (ASME) , 2011, Vol. 4, s. 1021-1026Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

A start-up of a gas turbine means that stress and forces are put on the machine. A start-up in cold climate conditions means that the forces are more critical since the material in the machine becomes more brittle. At a certain temperature the material is utilized to its limits (with appropriate margins applied) and for the SGT-600 ambient temperatures below -30°C (-22°F) become critical. In earlier installations in an arctic climate, an electric pre- heater has been utilized to prevent the critical components from becoming too brittle. This additional hardware costs money, is consuming auxiliary power and may contribute to unavailability. Another way to solve this issue may be to install material that is less brittle, but this will also increase the cost of the installation. Siemens is now applying an improved control logic during start-up, solving this issue in the software, without any additional hardware and avoiding unnecessary material changes. This new innovative start-up procedure is performing an automatic check of the stress levels before loading the machine, resulting in a safe and reliable start at temperatures below -30°C (-22°F). 

sted, utgiver, år, opplag, sider
The American Society of Mechanical Engineers (ASME) , 2011. Vol. 4, s. 1021-1026
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-69962DOI: 10.1115/GT2011-46409ISI: 000320677400098ISBN: 978-0-7918-5464-8 (tryckt)OAI: oai:DiVA.org:liu-69962DiVA, id: diva2:433659
Konferanse
ASME Turbo Expo 2011, Vancouver, British Columbia, Canada, June 6–10, 2011
Merknad

Paper No. GT2011-46409

Tilgjengelig fra: 2011-08-10 Laget: 2011-08-10 Sist oppdatert: 2016-05-26bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Moverare, Johan

Søk i DiVA

Av forfatter/redaktør
Moverare, Johan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 508 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf