Investigation of energy performance of newly built low-energy buildings in Sweden
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska högskolan.
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska högskolan.
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska högskolan.
2011 (engelsk)Inngår i: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 43, nr 10, s. 2822-2831Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Energy use in the built environment represents a large part of total energy use in Sweden and is oneimportant sector where energy conservation needs to be significantly improved in order to meet thenational implementation of the European goals. One key question that needs to be investigated in relationto these goals is the performance and implementation of passive or low-energy houses. This paperpresents results and an evaluation of a newly built house in an area with passive houses in Linköping,Sweden. Nine passive houses were built with the aim to be energy efficient, with an annual space heatingdemand of 21kWh/m2, and at the same time to have the same visual appearance as any other buildingin the surrounding area.This study evaluates the energy performance of a residential area with low-energy buildings basedon Building Energy Simulation (BES) (IDA ICE 4), and measurements from the real object. Both annualand hourly validation is performed using room by room modeling and internal heat gains. A novelapproach to internal heat gain modeling is presented using time-use data (TUD). The resultsshowpossibleimprovements in the design, the building envelope and in the heating control.

sted, utgiver, år, opplag, sider
Elsevier , 2011. Vol. 43, nr 10, s. 2822-2831
Emneord [en]
Passive house, Building Energy Simulation, Measurement, Evaluation, Energy performance
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-70470DOI: 10.1016/j.enbuild.2011.06.041ISI: 000295297700032OAI: oai:DiVA.org:liu-70470DiVA, id: diva2:439832
Prosjekter
Program Energisystem
Merknad
Funding Agencies|Swedish Energy Agency||Tilgjengelig fra: 2011-09-09 Laget: 2011-09-09 Sist oppdatert: 2017-12-08

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Molin, AndreasRohdin, PatrikMoshfegh, Bahram

Søk i DiVA

Av forfatter/redaktør
Molin, AndreasRohdin, PatrikMoshfegh, Bahram
Av organisasjonen
I samme tidsskrift
Energy and Buildings

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 204 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf