Aspects on Image Quality in Radiologic Evaluation of the Urinary Tract
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa. Linköpings universitet, Hälsouniversitetet.
2012 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The focus of this document is on image quality as one of the factors fundamental for the diagnostic process. With the rising number of procedures and the trend towards more complicated examinations, urinary tract investigations was chosen in this work as a good clinical model for evaluation of the factors influencing image quality and of the ways of evaluating image quality.

In paper I, a method is described for optimisation during the introduction of a new imaging system, with a focus on the maintenance of image quality relative to the older already optimised system. Image quality was assessed using the image criteria of the European guidelines for IVU with visual grading analysis. Equivalent image quality in image pairs was achieved at 30% of the dose. The CDRAD contrast-detail phantom makes it possible to find dose levels that give equal image quality using different imaging systems.

In paper II, the influence of bowel purgation on image quality in urography is questioned. The aim of this study was to compare bowel purgation and two other preparation methods; dietary restrictions and no preparation at all. Image quality was assessed according to European Commission criteria for excretory urography. The effectiveness of bowel purgation and the amount of residual gas were scored separately. The results of our study show that the preparation methods are of equal value and further use of bowel purgation before excretory urography cannot be justified.

In paper III, the image quality of the non-enhanced series is compared to a virtual noncontrast series obtained using two generations of dual-energy CT scanners and taking CT of the urinary tract as a model. The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, the OR range being 11.5–67.3 for the Definition and 2.1–2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than with Definition. Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images.

In paper IV, the accuracy of measurement of renal calculi in a dual-energy, virtual, nonenhanced-image series is compared to actual stone size and a single-energy image series in the phantom study. This study shows that detection of small stones is not reliable, despite better image quality, with the new DECT and that small stones will be missed with VNC imaging. With larger stones, the inherent measurement error with CT is magnified with VNC imaging.

sted, utgiver, år, opplag, sider
Linköping: Linköping University Electronic Press, 2012. , s. 69
Serie
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1298
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-76723ISBN: 978-91-7519-943-6 (tryckt)OAI: oai:DiVA.org:liu-76723DiVA, id: diva2:516406
Disputas
2012-05-18, Bohmansonssalen, Universitetssjukhuset, Örebro, 09:00 (svensk)
Opponent
Veileder
Tilgjengelig fra: 2012-04-18 Laget: 2012-04-18 Sist oppdatert: 2013-10-21bibliografisk kontrollert
Delarbeid
1. Reducing dose in urography while maintaining image quality - A comparison of storage phosphor plates and a flat-panel detector
Åpne denne publikasjonen i ny fane eller vindu >>Reducing dose in urography while maintaining image quality - A comparison of storage phosphor plates and a flat-panel detector
2006 (engelsk)Inngår i: European Radiology, ISSN 0938-7994, E-ISSN 1432-1084, Vol. 16, nr 1, s. 221-226Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The introduction of new flat-panel detector technology often forces us to accept too high dose levels as proposed by the manufacturers. We need a tool to compare the image quality of a new system with the accepted standard. The aim of this study was to obtain a comparable image quality for two systems - storage phosphor plates and a flat-panel system using intravenous urography (IVU) as a clinical model. The image quality figure was calculated using a contrast-detail phantom (CDRAD) for the two evaluated systems. This allowed us to set a dose for the flat-panel system that gave equivalent image quality to the storage phosphor plates. This reduced detector dose was used in an evaluation of clinical images to find out if the dose reduction from the phantom study indeed resulted in images of equal clinical image quality. The image quality was assessed using image criteria of the European guidelines for IVU with visual grading analysis. Equivalent image quality in image pairs was achieved at 30% of the dose. The CDRAD contrast-detail phantom makes it possible to find dose levels that give equal image quality using different imaging systems. © Springer-Verlag 2005.

Emneord
Digital radiography, Flat-panel detector, Image quality, Phantoms
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-50322 (URN)10.1007/s00330-005-2772-3 (DOI)
Tilgjengelig fra: 2009-10-11 Laget: 2009-10-11 Sist oppdatert: 2017-12-12bibliografisk kontrollert
2. Bowel preparation for excretory urography is not necessary: a randomized trial
Åpne denne publikasjonen i ny fane eller vindu >>Bowel preparation for excretory urography is not necessary: a randomized trial
2007 (engelsk)Inngår i: British Journal of Radiology, ISSN 0007-1285, E-ISSN 1748-880X, Vol. 80, nr 956, s. 617-624Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Despite the fact that computed tomography is becoming more commonly used to investigate the genitourinary tract, intravenous urography still plays an important role in uroradiology. The aim of this study was to compare bowel purgation and two other preparation methods — dietary restrictions and no preparations at all — in an attempt to find the optimal procedure for uniform practice. 210 consecutive patients were randomised to three preparation groups with 70 in each group. Group 1 received standard bowel purgation, Group 2 was instructed to fast, while Group 3 had no preparation at all. Irrespective of preparation, all patients underwent the same examination procedure. The examining radiographer and evaluating radiologists were unaware of the type of preparation given. Image quality was assessed according to European Commission criteria for excretory urography. The effectiveness of bowel purgation and the amount of residual gas were scored separately. There was no statistically significant difference in the proportions with fulfilled criteria between preparation Groups 1 and 2 and Groups 1 and 3. A criterion was regarded as fulfilled only when all three observers agreed. Assessment of the amount of residual faeces proved the effectiveness of our standard bowel purgation. The results of our study show equality of the evaluated preparation methods and cannot justify further use of bowel purgation before excretory urography.

HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-76719 (URN)10.1259/bjr/78311002 (DOI)000249951000005 ()
Tilgjengelig fra: 2012-04-18 Laget: 2012-04-18 Sist oppdatert: 2017-12-07bibliografisk kontrollert
3. Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study
Åpne denne publikasjonen i ny fane eller vindu >>Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study
Vise andre…
2012 (engelsk)Inngår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 53, nr 6, s. 689-694Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation.

Purpose: The aim of this study is to compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model.

Material and Methods: Thirty patients referred for evaluation of haematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard.

Results: The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR range 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition.

Conclusions: Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However the difference is smaller with the new compared to the older system.

sted, utgiver, år, opplag, sider
Informa Healthcare, 2012
Emneord
Dual-energy computed tomography, image quality, urinary tract imaging, virtual non-enhanced image series, bone-iodine differentiation
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-76721 (URN)10.1258/ar.2012.110661 (DOI)000306984000017 ()
Tilgjengelig fra: 2012-04-18 Laget: 2012-04-18 Sist oppdatert: 2017-12-07bibliografisk kontrollert
4. Accuracy of stone size measurement using dual-energy virtual non-contrast enhanced CT images: a phantom study
Åpne denne publikasjonen i ny fane eller vindu >>Accuracy of stone size measurement using dual-energy virtual non-contrast enhanced CT images: a phantom study
Vise andre…
(engelsk)Manuskript (preprint) (Annet vitenskapelig)
Abstract [en]

Background: Accurate estimation of calculus size is an important prediction factor for spontaneous passage. The method used for calculus-size estimation needs to be as precise as possible. Previous studies have shown that the image quality of virtual non-contrast (VNC) images obtained with the new generation of dual-energy CT (DECT) is still inferior compared to native images. However, the difference in assessed image quality compared to native series is smaler with the new than with the older system.

Purpose: The aim of this study is to evaluate the accuracy of measurements of renal calculi in a VNC image series obtained with the new generation of dual-energy CT, compared to actual stone size and single-energy image series in a phantom study.

Material and Methods: For the purpose of this study a ureter phantom was created. The phantom was scanned with DECT (Somatom Definition Flash) at three different radiation-dose settings with single and dual energy, first with water in the ureters then with i.v. contrast medium solution. At each energy level CDTI were set equal for single and dual-energy. VNC series were created. All image series were assessed for stone visibility and size.

Results: All calculi were visible in single- and dual-energy images with water in phantom tubes. With the VNC calculi in the size range 1.42 – 2.02 mm were missed. Results of intraobserver variability in investigated dose levels shows very good agreement between assessments of stone size by both evaluators, with correlation coefficient (CC) variying from 0.97 (95% CI 0.91–0.99) to 1.0 (95% CI 0.99–1.0). Results of correlation tests between the mean of maximal stone size and maximal stone size measured with electronic callipers show good agreement, with a CC variability from 0.93 (95% CI 0.76-0.98) to 0.99 (95% CI 0.96-0.99), a limit of agreement of "1.65 to 1.38 and bias "0.14. With one of the observers, the results of correlation tests in assessments made by the same reader of stone-size in dual-energy and VNC image series for corresponding dose levels show lower ICC for the low dose level, 0.77 (CI 0.36–0.93), with limits of agreement of -2.23–0.57 and bias "0.33.

Conclusions: This study shows that detection of small stones is not reliable despite better image quality with the new DECT and that small stones will be missed with VNC imaging. In larger stones, the inherent measurement error with CT is magnified with VNC imaging.

HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-76722 (URN)
Tilgjengelig fra: 2012-04-18 Laget: 2012-04-18 Sist oppdatert: 2013-10-21bibliografisk kontrollert

Open Access i DiVA

Aspects on Image Quality in Radiologic Evaluation of the Urinary Tract(1995 kB)4141 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1995 kBChecksum SHA-512
114df17df9bc0e0c8567363d91cafb2e89e6fb3d69e4f6a63f187ea9e4dd376885e64338715d3551907ea81c3535f34fdba5dbddca6b7884bfa3f6d9424124a8
Type fulltextMimetype application/pdf
omslag(2876 kB)143 nedlastinger
Filinformasjon
Fil COVER01.pdfFilstørrelse 2876 kBChecksum SHA-512
ccdf266d07634b30633cdb6b97186783faec8ca09dcbf9c3ffd5a7e21dafda2153178a34d83308abc67017cc6b1be843a3144b3772162192eacaa5e39340ee30
Type coverMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 4141 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 751 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf