liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Synthetic MRI of the brain in a clinical setting
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiologi. Linköpings universitet, Hälsouniversitetet.ORCID-id: 0000-0002-8857-5698
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Diagnostikcentrum, Röntgenkliniken i Linköping.ORCID-id: 0000-0002-7750-1917
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för klinisk och experimentell medicin, Neurologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Närsjukvården i centrala Östergötland, Neurologiska kliniken.
Vise andre og tillknytning
2012 (engelsk)Inngår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 53, nr 10, s. 1158-1163Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND:

Conventional magnetic resonance imaging (MRI) has relatively long scan times for routine examinations, and the signal intensity of the images is related to the specific MR scanner settings. Due to scanner imperfections and automatic optimizations, it is impossible to compare images in terms of absolute image intensity. Synthetic MRI, a method to generate conventional images based on MR quantification, potentially both decreases examination time and enables quantitative measurements.

PURPOSE:

To evaluate synthetic MRI of the brain in a clinical setting by assessment of the contrast, the contrast-to-noise ratio (CNR), and the diagnostic quality compared with conventional MR images.

MATERIAL AND METHODS:

Twenty-two patients had synthetic imaging added to their clinical MR examination. In each patient, 12 regions of interest were placed in the brain images to measure contrast and CNR. Furthermore, general image quality, probable diagnosis, and lesion conspicuity were investigated.

RESULTS:

Synthetic T1-weighted turbo spin echo and T2-weighted turbo spin echo images had higher contrast but also a higher level of noise, resulting in a similar CNR compared with conventional images. Synthetic T2-weighted FLAIR images had lower contrast and a higher level of noise, which led to a lower CNR. Synthetic images were generally assessed to be of inferior image quality, but agreed with the clinical diagnosis to the same extent as the conventional images. Lesion conspicuity was higher in the synthetic T1-weighted images, which also had a better agreement with the clinical diagnoses than the conventional T1-weighted images.

CONCLUSION:

Synthetic MR can potentially shorten the MR examination time. Even though the image quality is perceived to be inferior, synthetic images agreed with the clinical diagnosis to the same extent as the conventional images in this study.

sted, utgiver, år, opplag, sider
Sage Publications, 2012. Vol. 53, nr 10, s. 1158-1163
Emneord [en]
CNS, MR imaging, brain, technology assessment, imaging sequences
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-89641DOI: 10.1258/ar.2012.120195ISI: 000314077400015PubMedID: 23024181OAI: oai:DiVA.org:liu-89641DiVA, id: diva2:608602
Tilgjengelig fra: 2013-02-28 Laget: 2013-02-28 Sist oppdatert: 2017-11-16bibliografisk kontrollert
Inngår i avhandling
1. Clinical Applications of Synthetic MRI of the Brain
Åpne denne publikasjonen i ny fane eller vindu >>Clinical Applications of Synthetic MRI of the Brain
2017 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Magnetic Resonance Imaging (MRI) has a high soft-tissue contrast with a high sensitivity for detecting pathological changes in the brain. Conventional MRI is a time-consuming method with multiple scans that relies on the visual assessment of the neuroradiologist. Synthetic MRI uses one scan to produce conventional images, but also quantitative maps based on relaxometry, that can be used to quantitatively analyse tissue properties and pathological changes. The studies presented here apply the use of synthetic MRI of the brain in different clinical settings.

In the first study, synthetic MR images were compared to conventional MR images in 22 patients. The contrast, the contrast-to-noise ratio, and the diagnostic quality were assessed. Image quality was perceived to be inferior in the synthetic images, but synthetic images agreed with the clinical diagnoses to the same extent as the conventional images.

Patients with early multiple sclerosis were analysed in the second study. In patients with multiple sclerosis, contrast-enhancing white matter lesions are a sign of active disease and can indicate a need for a change in therapy. Gadolinium-based contrast agents are used to detect active lesions, but concern has been raised regarding the long-term effects of repeated use of gadolinium. In this study, relaxometry was used to evaluate whether pre-contrast injection tissue-relaxation rates and proton density can identify active lesions without gadolinium. The findings suggest that active lesions often have relaxation times and proton density that differ from non-enhancing lesions, but with some overlap. This makes it difficult to replace gadolinium-based contrast agent injection with synthetic MRI in the monitoring of MS patients.

Malignant gliomas are primary brain tumours with contrast enhancement due to a defective blood-brain barrier. However, they also grow in an infiltrative, diffuse manner, making it difficult to clearly delineate them from surrounding normal brain tissue in the diagnostic workup, at surgery, and during follow-up. The contrast-enhancing part of the tumour is easily visualised, but not the diffuse infiltration. In studies three and four, synthetic MRI was used to analyse the peritumoral area of malignant gliomas, and revealed quantitative findings regarding peritumoral relaxation changes and non-visible contrast enhancement suggestive of non-visible infiltrative tumour growth.

In conclusion, synthetic MRI provides quantitative information about the brain tissue and this could improve the diagnosis and treatment for patients.

sted, utgiver, år, opplag, sider
Linköping: Linköping University Electronic Press, 2017. s. 77
Serie
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1600
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-143032 (URN)10.3384/diss.diva-143032 (DOI)9789176854136 (ISBN)
Disputas
2017-12-13, Berzeliussalen, Campus US, Linköping, 09:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2017-11-16 Laget: 2017-11-16 Sist oppdatert: 2019-10-28bibliografisk kontrollert

Open Access i DiVA

Synthetic MRI of the brain in a clinical setting(1833 kB)343 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1833 kBChecksum SHA-512
b43f607bca50d00c9f3dd660515f5af670574ad088e92fbce821beb2e8bfc01f1f0d6b4d4930546ab96b10d57b39e2453afdd6cdf2588a21729e2c816fff7bce
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Blystad, IdaWarntjes, Jan Bertus MarcelSmedby, ÖrjanLandtblom, Anne-MarieLundberg, Peter

Søk i DiVA

Av forfatter/redaktør
Blystad, IdaWarntjes, Jan Bertus MarcelSmedby, ÖrjanLandtblom, Anne-MarieLundberg, Peter
Av organisasjonen
I samme tidsskrift
Acta Radiologica

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 343 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 764 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf