liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Force to restore the shape of an asymmetric extracorporeal tube as the basis for non-invasive pressure measurements.
Linköpings universitet, Institutionen för medicinsk teknik, Fysiologisk mätteknik. Linköpings universitet, Tekniska högskolan.
2002 (engelsk)Inngår i: International Journal of Artificial Organs, ISSN 0391-3988, E-ISSN 1724-6040, Vol. 25, nr 4, s. 281-289Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A zero-balance principle is described where intraluminal pressure is estimated from the counter force needed to restore the tube shape of an elastic extra corporeal tube. The aim was to optimise cross-sectional tube geometry for tube expansion due to pressure and to reduce the sensitivity to variation in mechanical tube characteristics using an experimental statistical and factorial design. The main application is pressure monitoring in blood and dialysate tubes during hemodialysis. Improving the monitoring of the dialysis process will reduce complications, such as sudden decreases in systemic blood pressure or occlusion at the artero-venous fistula. The factorial design indicated strong influence from the geometrical characteristics of the tube as well from the geometrical design parameters of the pressure transducer. We found a consistent relationship between the intraluminal pressure and the applied force needed to restore the tube shape. The modified cross-sectional tube geometry enhances measurement sensitivity and facilitates the desired behavior of tubes during pressure applications.

sted, utgiver, år, opplag, sider
2002. Vol. 25, nr 4, s. 281-289
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-116911PubMedID: 12027138OAI: oai:DiVA.org:liu-116911DiVA, id: diva2:801468
Tilgjengelig fra: 2015-04-09 Laget: 2015-04-09 Sist oppdatert: 2017-12-04

Open Access i DiVA

Fulltekst mangler i DiVA

PubMed

Personposter BETA

Ask, Per

Søk i DiVA

Av forfatter/redaktør
Ask, Per
Av organisasjonen
I samme tidsskrift
International Journal of Artificial Organs

Søk utenfor DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetric

pubmed
urn-nbn
Totalt: 239 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf