liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Fat Quantification in Skeletal Muscle Using Multigradient-Echo Imaging: Comparison of Fat and Water References
Skåne University Hospital, Sweden.
Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
Lund University, Sweden.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Radiofysikavdelningen US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.ORCID-id: 0000-0002-6189-0807
Vise andre og tillknytning
2016 (engelsk)Inngår i: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586, Vol. 43, nr 1, s. 203-212Artikkel i tidsskrift (Fagfellevurdert) Published
Resurstyp
Text
Abstract [en]

Purpose: To investigate the precision, accuracy, and repeatability of water/fat imaging-based fat quantification in muscle tissue using a large flip angle (FA) and a fat reference for the calculation of the proton density fat fraction (FF). Comparison is made to a small FA water reference approach. Materials and Methods: An Intralipid phantom and both forearms of six patients suffering from lymphedema and 10 healthy volunteers were investigated at 1.5T. Two multigradient-echo sequences with eight echo times and FAs of 10 degrees and 85 degrees were acquired. For healthy volunteers, the acquisition of the right arm was performed twice with repositioning. From each set, water reference FF and fat reference FF images were reconstructed and the average FF and the standard deviation were calculated within the subfascial compartment. The small FA water reference was considered the reference standard. Results: A high agreement was found between the small FA water reference and large FA fat reference methods (FF bias=0.31%). In this study, the large FA fat reference approach also resulted in higher precision (38% smaller FF standard deviation in homogenous muscle tissue), but no significant difference in repeatability between the various methods was detected (coefficient of repeatability of small FA water reference approach 0.41%). Conclusion: The precision of fat quantification in muscle tissue can be increased with maintained accuracy using a larger flip angle, if a fat reference instead of a water reference is used.

sted, utgiver, år, opplag, sider
WILEY-BLACKWELL , 2016. Vol. 43, nr 1, s. 203-212
Emneord [en]
fat quantification; water; fat imaging; skeletal muscle; water reference; internal fat reference
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-125322DOI: 10.1002/jmri.24972ISI: 000368741400019PubMedID: 26095018OAI: oai:DiVA.org:liu-125322DiVA, id: diva2:906206
Merknad

Funding Agencies|Research Council of Southeast Sweden [FORSS-311941]; Knut and Alice Wallenberg Foundation; Stiftelsen for cancerforskning vid Onkologiska kliniken vid Universitetssjukhuset MAS; Skane County Councils Research and Development Foundation; Swedish Cancer Society; Allmanna Sjukhusets i Malmo Stiftelse for bekampande av cancer

Tilgjengelig fra: 2016-02-24 Laget: 2016-02-19 Sist oppdatert: 2019-06-14

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Romu, ThobiasDahlqvist Leinhard, Olof

Søk i DiVA

Av forfatter/redaktør
Romu, ThobiasDahlqvist Leinhard, Olof
Av organisasjonen
I samme tidsskrift
Journal of Magnetic Resonance Imaging

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 1168 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf