liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Impact of Center Experience on Patient Radiation Exposure During Transradial Coronary Angiography and Percutaneous Intervention: A Patient-Level, International, Collaborative, Multi-Center Analysis
University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
Hamilton Health Sciences, Hamilton, Ontario, Canada.
Department of Medicine, Columbia University, New York, NY.
Vise andre og tillknytning
2016 (engelsk)Inngår i: Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease, ISSN 2047-9980, E-ISSN 2047-9980, Vol. 5, nr 6Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background-—The adoption of the transradial (TR) approach over the traditional transfemoral (TF) approach has been hampered by concerns of increased radiation exposure—a subject of considerable debate within the field. We performed a patient-level, multi-center analysis to definitively address the impact of TR access on radiation exposure. Methods and Results-—Overall, 10 centers were included from 6 countries—Canada (2 centers), United Kingdom (2), Germany (2), Sweden (2), Hungary (1), and The Netherlands (1). We compared the radiation exposure of TR versus TF access using measured dose-area product (DAP). To account for local variations in equipment and exposure, standardized TR:TF DAP ratios were constructed per center with procedures separated by coronary angiography (CA) and percutaneous coronary intervention (PCI). Among 57 326 procedures, we demonstrated increased radiation exposure with the TR versus TF approach, particularly in the CA cohort across all centers (weighted-average ratios: CA, 1.15; PCI, 1.05). However, this was mitigated by increasing TR experience in the PCI cohort across all centers (r=0.8; P=0.005). Over time, as a center transitioned to increasing TR experience (r=0.9; P=0.001), a concomitant decrease in radiation exposure occurred (r=0.8; P=0.006). Ultimately, when a center’s balance of TR to TF procedures approaches 50%, the resultant radiation exposure was equivalent. Conclusions-—The TR approach is associated with a modest increase in patient radiation exposure. However, this increase is  eliminated when the TR and TF approaches are used with equal frequency—a guiding principle for centers adopting the TR approach.

sted, utgiver, år, opplag, sider
Wiley-Blackwell, 2016. Vol. 5, nr 6
Emneord [en]
coronary angiography, dose-area product, percutaneous coronary intervention, radial artery catheterisation, radiation, transradial
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-129002DOI: 10.1161/JAHA.116.003333ISI: 000386712700040PubMedID: 27247332OAI: oai:DiVA.org:liu-129002DiVA, id: diva2:934142
Merknad

Funding agencies: General Electric (GE) Healthcare; TeraRecon Inc.; Saul and Edna Goldfarb Research Chair in Cardiac Imaging

Tilgjengelig fra: 2016-06-08 Laget: 2016-06-08 Sist oppdatert: 2017-11-30

Open Access i DiVA

fulltext(817 kB)121 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 817 kBChecksum SHA-512
11cff4550670b91ef31a787bbb7ba70871aa1df0241036d22d05c138bf28dbf60b8191ebeb0e3eede432baeea148b859638b1c7a0553518a6387693fb2327efb
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Sandborg, Michael

Søk i DiVA

Av forfatter/redaktør
Sandborg, Michael
Av organisasjonen
I samme tidsskrift
Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 121 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 125 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf