liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Establishing the European diagnostic reference levels for interventional cardiology
STUK Radiat and Nucl Safety Author, Finland.
Univ Belgrade, Serbia.
Belgian Nucl Res Ctr SCK CEN, Belgium.
Univ Hosp Rijelca, Croatia.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 54, s. 42-48Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Interventional cardiac procedures may be associated with high patient doses and therefore require special attention to protect the patients from radiation injuries such as skin erythema, cardiovascular tissue reactions or radiation-induced cancer. In this study, patient exposure data is collected from 13 countries (37 clinics and nearly 50 interventional rooms) and for 10 different procedures. Dose data was collected from a total of 14,922 interventional cardiology procedures. Based on these data European diagnostic reference levels (DRL) for air kerma-area product are suggested for coronary angiography (CA, DRL = 35 Gy cm(2)), percutaneous coronary intervention (PCI, 85 Gy cm(2)), transcatheter aortic valve implantation (TAVI, 130 Gy cm(2)), electrophysiological procedures (12 Gy cm(2)) and pacemaker implantations Pacemaker implantations were further divided into single-chamber (2.5 Gy cm(2)) and dual chamber (3.5 Gy cm(2)) procedures and implantations of cardiac resynchronization therapy pacemaker (18 Gy cm(2)). Results show that relatively new techniques such as TAVI and treatment of chronic total occlusion (CTO) often produce relatively high doses, and thus emphasises the need for use of an optimization tool such as DRL to assist in reducing patient exposure. The generic DRL presented here facilitate comparison of patient exposure in interventional cardiology.

Ort, förlag, år, upplaga, sidor
ELSEVIER SCI LTD , 2018. Vol. 54, s. 42-48
Nyckelord [en]
Diagnostic reference levels; Interventional cardiology
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:liu:diva-152392DOI: 10.1016/j.ejmp.2018.09.012ISI: 000447271300006PubMedID: 30337009OAI: oai:DiVA.org:liu-152392DiVA, id: diva2:1259627
Tillgänglig från: 2018-10-30 Skapad: 2018-10-30 Senast uppdaterad: 2019-05-01

Open Access i DiVA

fulltext(787 kB)4 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 787 kBChecksumma SHA-512
af8b6b7c0ef854b5ba65c219eeb0dad84781ae5c083026c5eb9b7f6c34bf65d60f14f3548c125faba059596ee99882af4e0b735e961e19a5a927b3dc71f67e0e
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Sandborg, Michael

Sök vidare i DiVA

Av författaren/redaktören
Sandborg, Michael
Av organisationen
Avdelningen för radiologiska vetenskaperMedicinska fakultetenCentrum för medicinsk bildvetenskap och visualisering, CMIVMedicinsk strålningsfysik
I samma tidskrift
Physica medica (Testo stampato)
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 4 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 38 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf