High performance electrochemical biosensor based on 3D nitrogen-doped reduced graphene oxide electrode and tetrahedral DNA nanostructure
Tsinghua Peking Joint Ctr Life Sci, Peoples R China.
Linköpings universitet, Institutionen för fysik, kemi och biologi, Biomolekylär och Organisk Elektronik. Linköpings universitet, Tekniska fakulteten. Nanjing Tech Univ, Peoples R China.
Chinese Acad Sci, Peoples R China.
Peking Univ, Peoples R China.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Talanta: The International Journal of Pure and Applied Analytical Chemistry, ISSN 0039-9140, E-ISSN 1873-3573, Vol. 194, s. 273-281Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In this study, an electrochemical biosensor was developed for highly sensitive and specific detection of target miRNA-155. The structure was formed by the hybridization of a tetrahedral DNA nanostructure-based biomolecular probe assembled on 3D nitrogen-doped reduced graphene oxide/gold nanoparticles (3D N-doped rGO/AuNPs) electrode surface. Upon addition of target miRNA-155, the gold and silver nanorod/thionine/complementary DNA (AuAgNR/Thi/F) was hybridized with the target, and used for signal amplification, catalyzing the reduction of Thi as an electron mediator. Due to the signal amplification by the enhanced immobilization of DNA on the surface of 3D N-doped rGO/AuNPs electrode and AuAgNR/Thi, coupling the low background signal produced by blank solution, electrochemical performance of the device was optimized to be proportional to miRNA-155 concentration in the range of 1 x 10(-11) to 1 x 10(-4) M with a detection limit of 1 x 10(-12) M. In addition, direct detection in serum is demonstrated with high specificity. Thus, this biosensor is potentially applicable for microRNA detection in medical research and early clinical diagnosis.

Ort, förlag, år, upplaga, sidor
ELSEVIER SCIENCE BV , 2019. Vol. 194, s. 273-281
Nyckelord [en]
3D N-doped rGO/AuNPs; MicroRNA; AuAgNR; Tetrahedral DNA; Electrochemical biosensor
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:liu:diva-154541DOI: 10.1016/j.talanta.2018.09.110ISI: 000456899700036PubMedID: 30609531OAI: oai:DiVA.org:liu-154541DiVA, id: diva2:1290530
Anmärkning

Funding Agencies|National Natural Science Foundation of China [2127369, 61704078]; Tsinghua-Peking Joint Center for Life Sciences post-doctoral fund; Natural Science Foundation of Jiangsu Province of China [BK20160990]

Tillgänglig från: 2019-02-20 Skapad: 2019-02-20 Senast uppdaterad: 2019-03-26

Open Access i DiVA

Publikationen är tillgänglig i fulltext från 2020-10-09 12:20
Tillgänglig från 2020-10-09 12:20

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Ning, Weihua
Av organisationen
Biomolekylär och Organisk ElektronikTekniska fakulteten
I samma tidskrift
Talanta: The International Journal of Pure and Applied Analytical Chemistry
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 11 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf