CE Article: Transfer Rate of Pathogens Through In Vitro Contaminated Venous Port Membranes Varies With Species, Concentration, and Injection Technique
Department of Anaesthesia and Intensive Care Medicine, Ryhov County Hospital, Jönköping and Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
Microbiology Laboratory, Division of Medical Diagnosis, Jönköping County, Sweden.
Department of Anaesthesia and Intensive Care Medicine, Ryhov County Hospital, Sweden.
Department of Infectious Diseases and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Journal of the Association for Vascular Access, ISSN 1552-8855, Vol. 24, nr 3, s. 16-22Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Introduction: Reliable venous access is a cornerstone in delivery of cytotoxic drugs, and subcutaneous venous ports (SVPs) are commonly used. Pocket infection is a major complication that can lead to SVP removal and treatment delay. Consensus is lacking whether a suspected port infection is a contraindication to continued use. Our aim was to examine the extent of pathogen transfer into a SVP by puncturing an in vitro contaminated injection membrane and to evaluate techniques to reduce this transmission.

Method: Four pathogens were applied to SVP membranes in concentrations mimicking clinical infection, and the membranes punctured with or without flow through the needle. The port was then flushed with saline, and samples from the outlet were analyzed.

Results: Microorganisms were transported into the SVP when puncturing the contaminated membrane. The number of microorganisms transferred was related to the concentration of microorganisms on the membrane and varied with species. Flow through the needle during insertion reduced the number of bacteria transported through the SVP membrane.

Discussion: Our results indicate that a limited number of pathogens are likely to be introduced into the SVP chamber when puncturing a contaminated membrane. The number of bacteria transferred could be reduced by applying flow during puncture.

Ort, förlag, år, upplaga, sidor
2019. Vol. 24, nr 3, s. 16-22
Nationell ämneskategori
Infektionsmedicin
Identifikatorer
URN: urn:nbn:se:liu:diva-190067DOI: 10.2309/j.java.2019.003.002OAI: oai:DiVA.org:liu-190067DiVA, id: diva2:1712102
Tillgänglig från: 2022-11-20 Skapad: 2022-11-20 Senast uppdaterad: 2022-12-08

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext
Infektionsmedicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 14 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf