Reduction in the incidence of awareness using BIS monitoring
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Anestesiologi. Östergötlands Läns Landsting, Anestesi- och operationscentrum, Intensivvårdskliniken US.
2004 (Engelska)Ingår i: Acta Anaesthesiologica Scandinavica, ISSN 0001-5172, E-ISSN 1399-6576, Vol. 48, nr 1, s. 20-26Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: Explicit recall (ER) is evident in approximately 0.2% of patients given general anaesthesia including muscle relaxants. This prospective study was performed to evaluate if cerebral monitoring using BIS to guide the conduction of anaesthesia could reduce this incidence significantly. Patients and methods: A prospective cohort of 4945 consecutive surgical patients requiring muscle relaxants and/or intubation were monitored with BIS and subsequently interviewed for ER on three occasions. BIS values between 40 and 60 were recommended. The results from the BIS-monitored group of patients was compared with a historical group of 7826 similar cases in a previous study when no cerebral monitoring was used. Results: Two patients in the BIS-monitored group, 0.04%, had ER as compared with 0.18% in the control group (P < 0.038). Both BIS-monitored patients with ER were aware during intubation when they had high BIS values (>60) for 4 min and more than 10 min, respectively. However, periods with high BIS = 4 min were also evident in other patients with no ER. Episodes with high BIS, 4 min or more, were found in 19% of the monitored patients during induction, and in 8% of cases during maintenance. Conclusions: The use of BIS monitoring during general anaesthesia requiring endotracheal intubation and/or muscle relaxants was associated with a significantly reduced incidence of awareness as compared with a historical control population.

Ort, förlag, år, upplaga, sidor
2004. Vol. 48, nr 1, s. 20-26
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-24260DOI: 10.1111/j.1399-6576.2004.00260.xLokalt ID: 3864OAI: oai:DiVA.org:liu-24260DiVA, id: diva2:244577
Tillgänglig från: 2009-10-07 Skapad: 2009-10-07 Senast uppdaterad: 2017-12-13

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Lennmarken, Claes

Sök vidare i DiVA

Av författaren/redaktören
Lennmarken, Claes
Av organisationen
HälsouniversitetetAnestesiologiIntensivvårdskliniken US
I samma tidskrift
Acta Anaesthesiologica Scandinavica
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 59 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf