Reliability of 24-hour oesophageal pH monitoring under standardized conditions
Linköpings universitet, Institutionen för biomedicin och kirurgi, Kirurgi. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för biomedicin och kirurgi, Kirurgi. Linköpings universitet, Hälsouniversitetet.
2002 (Engelska)Ingår i: Scandinavian Journal of Gastroenterology, ISSN 0036-5521, E-ISSN 1502-7708, Vol. 37, nr 1, s. 6-8Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

BACKGROUND:

Twenty-four-hour pH monitoring is an investigation technique that can give both false-positive and false-negative results, depending on patient factors such as diet and different activities. The aim was to study the reproducibility of 24-h oesophageal pH monitoring under as standardized conditions as possible in patients with symptoms of gastro-oesophageal reflux disease.

METHODS:

Antimony pH electrodes were used in 22 adult patients who were investigated twice, 6 weeks apart, under identical conditions. They were hospitalized and were served a standardized diet which had been tested to contain no lower than pH 5.0. Neither coffee nor smoking was allowed. The patients had to refrain from proton-pump inhibitors for 10 days and H2 blockers for 2 days prior to the investigation. The paired t test was used.

RESULTS:

There was no significant difference in total reflux time, upright or supine reflux time, or longest reflux periods between the two test occasions. However, there were discordant results in six patients who had normal total reflux time on one test occasion but pathological results on the other.

CONCLUSION:

Since the biological variability of gastro-oesophageal reflux is not negligible from time to time, a normal 24-h oesophageal pH test should be assessed with caution.

Ort, förlag, år, upplaga, sidor
2002. Vol. 37, nr 1, s. 6-8
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-25024DOI: 10.1080/003655202753387275PubMedID: 11843037Lokalt ID: 9445OAI: oai:DiVA.org:liu-25024DiVA, id: diva2:245350
Tillgänglig från: 2009-10-07 Skapad: 2009-10-07 Senast uppdaterad: 2017-12-13Bibliografiskt granskad
Ingår i avhandling
1. Success and failure of conventional and laparoscopic fundoplication in gastro-oesophageal reflux disease
Öppna denna publikation i ny flik eller fönster >>Success and failure of conventional and laparoscopic fundoplication in gastro-oesophageal reflux disease
2003 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

The outcome of antireflux surgery in a single institution during two decades is presented.

101 consecutive patients operated with open partial2 70° fundoplication and crural repair during 1982-1989 were prospectively analysed. All stages ofpreoperative oesophagitis were represented. Reflux competence, symptomatology, and postoperative side-effects were evaluated six months and ten years postoperatively. Recurrence (8%) was more common in patients who had severe oesophagitis before operation. The operative method is effective for long-term reflux control, it does not cause dysphagia, and it has few side-effect. Some months prior to the introduction oflaparoscopic fundoplication our unit had changed from partial to total fundoplication as a standard operation for gastro-oesophageal reflux disease (GORD). It was then convenient to perform the total Nissen fundoplication laparoscopically. All 50 patients operated with laparoscopic technique during a 30-months period 1992-1994 were prospectively compared with 21 patients operated with open technique. Nine patients were converted and then analysed in the open group. We tried to select patients with uncomplicated disease for laparoscopy but 7 patients in this group had severe disease diagnosed at preoperative endoscopy or/and at operation. In the open group 9 patients had severe disease. The patients were investigated six months, two years, and five years postoperatively. Early postoperative manometry was prognostic for recurrence. At long term follow-up the reflux control was similar, 10% of the patients operated with laparoscopy had recurrence and 8% of the patients operated with open technique.

Summer 1994 to spring 1998 we included 93 patients with uncomplicated GORD in a randomised clinical trial between laparoscopic and open 360° floppy Nissen fundoplication with crural repair. 45 patients were operated on laparoscopically and 48 patients underwent laparotomy. Only one patient was converted and then analysed in the laparotomy group. The patients were investigated before operation, half a year after and at long-term follow-up (33-79 months postoperatively). Long-term follow up also included endoscopy. Operation time was significantly longer for laparoscopy compared to laparotomy, 155.6 (±36.5) minutes and 104.3 (±30.7) minutes respectively (p<0.05). Laparoscopy patients had significantly shorter hospital stay, 3.6 (±1.9) days, compared to 5.8 (±1. 7) days for laparotomy patients. Sick leaves were 20.7 (±9.9) days for laparoscopy patients and 28.3 (14.7) for laparotomy patients. The difference was significant (p<0.05). Early postoperative reflux control was similar for laparoscopic and conventional fundoplication. Early side-effects were more frequent after laparoscopy. Significantly less laparoscopy patients were satisfied at long-term follow-up; only 62% of the laparoscopy patients were satisfied compared to 91% of the laparotomy patients.

We have investigated the mechanisms and anatomical failures in twenty-one patients reoperated after laparoscopic total fundoplication. Recurrent heartburn occurs when wrong part of the stomach is used for the fundoplication. Dysphagia after failed laparoscopic total fundoplication is caused by hiatal fibrosis or other mechanical causes rather than a normal and tight fundoplication.

Also the reproducibility of an important diagnostic tool for GORD, the 24-hour pH monitoring, was evaluated. Twenty-two adult patients admitted to The Oesophageal Laboratory for 24-hour pH monitoring were investigated twice, six weeks apart, under identical conditions. The test was strictly standardised with the use of an antimony pH- probe and the patients hospitalised during 24 hours. We found that a normal 24-hour pH test should be assessed with caution because the biological variability of gastro-oesophageal reflux is not negligible from time to time.

Ort, förlag, år, upplaga, sidor
Linköping: Linköpings universitet, 2003. s. 55
Serie
Linköping University Medical Dissertations, ISSN 0345-0082 ; 796
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
urn:nbn:se:liu:diva-25644 (URN)10019 (Lokalt ID)91-7373-554-X (ISBN)10019 (Arkivnummer)10019 (OAI)
Disputation
2003-06-06, Berzeliussalen, Hälsouniversitet, Linköping, 09:00 (Svenska)
Opponent
Tillgänglig från: 2009-10-08 Skapad: 2009-10-08 Senast uppdaterad: 2012-10-10Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Franzén, Thomas

Sök vidare i DiVA

Av författaren/redaktören
Franzén, Thomas
Av organisationen
KirurgiHälsouniversitetet
I samma tidskrift
Scandinavian Journal of Gastroenterology
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 125 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf