liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Multivariate optimisation of electrochemically pre-treated electrodes used in a voltammetric electronic tongue
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för fysik, kemi och biologi, Tillämpad Fysik.
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för fysik, kemi och biologi, Tillämpad Fysik.
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för fysik, kemi och biologi, Tillämpad Fysik.
2004 (Engelska)Ingår i: Analytica Chimica Acta, ISSN 0003-2670, E-ISSN 1873-4324, Vol. 519, nr 1, s. 39-46Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The use of experimental design as a tool to optimise electrochemically cleaned electrodes applied in a voltammetric electronic tongue is described. A simple and quick activation of electrode surfaces is essential for this type of device, especially for on-line applications in industrial processes. The electronic tongue consisted of four metal electrodes, e.g. Au, Ir, Pt, and Rh in a three-electrode configuration. Current was measured as a function of large potential pulses of decreasing amplitude applied to each electrode. Preliminary results showed that electrochemical cleaning activated the electrode surfaces to similar extent as polishing. Settings of potential and time for each electrode was determined with experimental design in a solution containing 1.0 mM K 4[Fe(CN)6] in 0.1 M phosphate buffer (pH 6.8). Electrode surfaces were deactivated in-between measurements in a complex liquid, like tea. Optimal settings for potential and time in the electrochemical cleaning procedure at each electrode were chosen at recoveries of 100% (compared to polished electrodes). The recoveries were larger than 100% when too large potentials and times were applied. This could be explained by the fact that the electrode areas increased and therefore also the current responses. Principal component analysis (PCA) was used to investigate the stability of the electrode settings at 100% recoveries. No obvious trends of drift in the signals were found. © 2004 Elsevier B.V. All rights reserved.

Ort, förlag, år, upplaga, sidor
2004. Vol. 519, nr 1, s. 39-46
Nyckelord [en]
Electrode pre-treatment, Electronic tongue, Experimental design, Optimisation, Principal component analysis and voltammetry
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:liu:diva-45664DOI: 10.1016/j.aca.2004.03.070OAI: oai:DiVA.org:liu-45664DiVA, id: diva2:266560
Tillgänglig från: 2009-10-11 Skapad: 2009-10-11 Senast uppdaterad: 2017-12-13

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Holmin, SusanneKrantz-Rülcher, ChristinaWinquist, Fredrik

Sök vidare i DiVA

Av författaren/redaktören
Holmin, SusanneKrantz-Rülcher, ChristinaWinquist, Fredrik
Av organisationen
Tekniska högskolanTillämpad Fysik
I samma tidskrift
Analytica Chimica Acta
Teknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 109 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf