liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Bone formation after 4 weeks around blood-plasma-modified titanium implants with varying surface topographies: An in vivo study
Göransson, A., Department of Biomaterial Science, Institute of Surgical Science, Göteborg University, Göteborg 40530, Sweden, Department of Prosthetic Dentistry/Dental Material Science, Box 412, Göteborg University, Göteborg 40530, Sweden.
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för fysik, kemi och biologi.
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för fysik, kemi och biologi, Tillämpad Fysik.
Department of Biomaterial Science, Institute of Surgical Science, Göteborg University, Göteborg 40530, Sweden, Department of Prosthetic Dentistry/Dental Material Science, Box 412, Göteborg University, Göteborg 40530, Sweden.
2003 (Engelska)Ingår i: Biomaterials, ISSN 0142-9612, E-ISSN 1878-5905, Vol. 24, nr 2, s. 197-205Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The aim of the present study was to investigate and compare the stability and bone ingrowth capacity to screw-shaped titanium implants with five different surface treatments. The implants were: (1) standard turned with a thin blood plasma coat (TP), (2) NaOH-etched dito with pore size 0.2-0.3µm (E), (3) NaOH-etched with pore size 0.2-0.3µm and a thin blood plasma coat (EP), (4) electrochemically oxidised with pore size 1-2µm (O), (5) electrochemically oxidised with pore size 1-2µm and a thin blood plasma coat (OP). A total of 66 implants were divided into the above-described five groups and inserted for 4 weeks into tibia and femur of 11 rabbits. The implants were evaluated by resonance frequency (RF) measurements at the time of insertion and removal, and analysed histomorphometrically at removal. The RF measurements showed that the implant stability was lower in soft bone compared to dense and increased with time. No significant differences were observed between the different surface modifications. The histomorphometric analysis revealed no statistically significant differences between the implants regarding bone-to-metal contact (BMC) and bone area inside the threads (BA). The above results indicate that thin blood plasma-coated and non-coated screw-shaped titanium implants with turned, NaOH-etched and electrochemically etched surface profiles integrate similarly to bone at 1 month of implantation. © 2002 Elsevier Science Ltd. All rights reserved.

Ort, förlag, år, upplaga, sidor
2003. Vol. 24, nr 2, s. 197-205
Nyckelord [en]
Blood-plasma-coated, Pores, Surface characterisation, Surface modification, Titanium implants, Titanium oxide
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:liu:diva-46757DOI: 10.1016/S0142-9612(02)00277-6OAI: oai:DiVA.org:liu-46757DiVA, id: diva2:267653
Tillgänglig från: 2009-10-11 Skapad: 2009-10-11 Senast uppdaterad: 2021-09-17
Ingår i avhandling
1. Blood protein coated model biomaterials: preparation, and cell and tissue response
Öppna denna publikation i ny flik eller fönster >>Blood protein coated model biomaterials: preparation, and cell and tissue response
2003 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Solid biomaterials are widely used in bone and in soft tissue applications. Problems may then arise due to a prolonged inflammation in the proximity of the implant, resulting in the formation of a fibrous capsule and a low vascularisation near the interface.

The formation of a blood plasma clot is the starting point of a normal wound healing process. One hypothesis in this thesis work was that a thin immobilised blood plasma clot may improve the integration during the early wound healing period. Model surfaces were made from titanium and silicon, and nm-μm thick blood plasma clots or protein multilayers immobilised onto the surfaces. Another hypothesis was that a submicron surface porosity further improves the integration process, and to study this some of the titanium surfaces were etched in sodium hydroxide, a treatment that resulted in 200 nm wide pores. Such porous titanium surfaces adsorbed 2 to 11 times more albumin and lgG in vitro than the corresponding smooth surfaces at varied pH and protein concentrations.

The blood plasma clot coated submicron porous titanium samples were implanted subcutaneously in the back of the rat or in rabbit bone. The soft tissue response was investigated after 3 or 24 hours and the fibrous encapsulation and vessel formation after 7 or 28 days of implantation. The bone ingrowth and the implant stability in the rabbit bone were investigated after 4 weeks of implantation.

The monocyte response on multilayer plasma protein coated surfaces was investigated through the analysis of tumor necrosis factor α (TNF-α) and interleukin-10 (IL-10) concentrations in the culture medium, the proportions of Annexin V and propidium iodide (PI) positive cells, and the amounts of nucleated cells. In parallel, the stability of the protein layers and the activation of the complement and coagulation cascades were investigated in vitro by ellipsometry.

The results from the monocyte culture and animal experiments show that the early soft tissue inflammatory response and vascularisation can be modulated through the introduction of a surface porosity and by the immobilised protein and plasma clot coatings. However, no significant differences were observed between the different surface modifications in rabbit bone with respect to bone-to-metal contact or percentage of bone area inside the threads.

Ort, förlag, år, upplaga, sidor
Linköping: Linköping University, 2003. s. 44
Serie
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 798
Nationell ämneskategori
Medicinsk bioteknologi
Identifikatorer
urn:nbn:se:liu:diva-179309 (URN)9173735930 (ISBN)
Disputation
2003-03-14, hörsal Planck, Fysikhuset, Linköpings universitet, Linköping, 09:00
Opponent
Tillgänglig från: 2021-09-24 Skapad: 2021-09-17 Senast uppdaterad: 2023-02-28Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Jansson, EvaTengvall, Pentti

Sök vidare i DiVA

Av författaren/redaktören
Jansson, EvaTengvall, Pentti
Av organisationen
Tekniska högskolanInstitutionen för fysik, kemi och biologiTillämpad Fysik
I samma tidskrift
Biomaterials
Teknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 185 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf