Causes of multimodality of efficiency gain distributions in accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling
Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik. Linköpings universitet, Tekniska högskolan.
2009 (Engelska)Självständigt arbete på avancerad nivå (masterexamen), 20 poäng / 30 hpStudentuppsats (Examensarbete)
Abstract [en]

Fixed-collision correlated sampling for Monte Carlo (MC) simulations is a method which can be used in order to shorten the simulation time for brachytherapy treatment planning in a 3D patient geometry. The increased efficiency compared to conventional MC simulation is measured by efficiency gain. However, a previous study showed that, in some cases, PDFs (probability density functions) of estimates of the efficiency gain, simulated using resampling and other MC methods, were multimodal with values below 1. This means that the method was less effective than conventional sampling for these cases. The aims of this thesis were to trace the causes of the multimodal distributions and to propose techniques to mitigate the problem caused by photons with high statistical weights.Two simulation environments were used for the study case, a homogeneous and a heterogeneous environment. The homogenous environment consisted of a water sphere with the radius 100mm. For the heterogeneous environment a cylindrical block of tungsten alloy (diameter 15 mm, height 2.5 mm) was placed in the water sphere. The sphere was divided into an array of cubic voxels of size 2.5 mm x 2.5 mm x 2.5 mm for dose calculations. A photon source was positioned in the middle of the water sphere and emitted photons with the energy 400 keV.It was found that the low values and multimodal PDFs for the efficiency gain estimates originated from photons depositing high values of energy in some voxels in the heterogeneous environment. The high energy deposits were due to extremely high statistical weights of photons interacting repeatedly in the highly attenuating tungsten cylinder. When photon histories contributing to the rare events of high energy deposits (outliers) were removed, the PDFs became uni-modal and efficiency gain increased. However, removing outliers will cause results to be biased calling for other techniques to handle the problem with high statistical weights.One way to resolve the problem in the current implementation of the fixed-collision correlated sampling scheme in PTRAN (the MC code used) could be to split photons with high statistical weights into several photons with the same sum weight as the initial photon. The splitting of photons will result in more time consuming simulations in areas with high attenuation coefficients, which may not be the areas of interest. This could be resolved by using Russian roulette, eliminating some of the photons with high statistical weight in such areas.Fixed-collision correlated sampling for Monte Carlo (MC) simulations is a method which can be used in order to shorten the simulation time for brachytherapy treatment planning in a 3D patient geometry. The increased efficiency compared to conventional MC simulation is measured by efficiency gain. However, a previous study showed that, in some cases, PDFs (probability density functions) of estimates of the efficiency gain, simulated using resampling and other MC methods, were multimodal with values below 1. This means that the method was less effective than conventional sampling for these cases. The aims of this thesis were to trace the causes of the multimodal distributions and to propose techniques to mitigate the problem caused by photons with high statistical weights.Two simulation environments were used for the study case, a homogeneous and a heterogeneous environment. The homogenous environment consisted of a water sphere with the radius 100mm. For the heterogeneous environment a cylindrical block of tungsten alloy (diameter 15 mm, height 2.5 mm) was placed in the water sphere. The sphere was divided into an array of cubic voxels of size 2.5 mm x 2.5 mm x 2.5 mm for dose calculations. A photon source was positioned in the middle of the water sphere and emitted photons with the energy 400 keV.It was found that the low values and multimodal PDFs for the efficiency gain estimates originated from photons depositing high values of energy in some voxels in the heterogeneous environment. The high energy deposits were due to extremely high statistical weights of photons interacting repeatedly in the highly attenuating tungsten cylinder. When photon histories contributing to the rare events of high energy deposits (outliers) were removed, the PDFs became uni-modal and efficiency gain increased. However, removing outliers will cause results to be biased calling for other techniques to handle the problem with high statistical weights.One way to resolve the problem in the current implementation of the fixed-collision correlated sampling scheme in PTRAN (the MC code used) could be to split photons with high statistical weights into several photons with the same sum weight as the initial photon. The splitting of photons will result in more time consuming simulations in areas with high attenuation coefficients, which may not be the areas of interest. This could be resolved by using Russian roulette, eliminating some of the photons with high statistical weight in such areas.

Ort, förlag, år, upplaga, sidor
2009. , s. 48
Nyckelord [en]
Monte Carlo simulations, brachytherapy, efficiency gain
Nationell ämneskategori
Medicinsk laboratorie- och mätteknik
Identifikatorer
URN: urn:nbn:se:liu:diva-56468ISRN: LiTH-IMT/MI30-A-EX--09/487--SEOAI: oai:DiVA.org:liu-56468DiVA, id: diva2:319414
Ämne / kurs
Medicinsk informatik
Presentation
2009-12-17, Läderbaggen, Linköping, 13:15 (Engelska)
Uppsök
fysik/kemi/matematik
Handledare
Examinatorer
Tillgänglig från: 2010-05-25 Skapad: 2010-05-17 Senast uppdaterad: 2012-09-27Bibliografiskt granskad

Open Access i DiVA

fulltext(2240 kB)268 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2240 kBChecksumma SHA-512
004c00c88c7701248b3db024e258c90413bf67560650b54dd35eff8664145479630047fc1c7ee76defad5d8a1b6cd32898eab5f8306d3b2731557e7b27267db1
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Deniz, Daniel
Av organisationen
Medicinsk informatikTekniska högskolan
Medicinsk laboratorie- och mätteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 268 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 428 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf