Two- and three-dimensional CT measurements of urinary calculi length and width: a comparative study
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. University of Örebro, Sweden.
University of Örebro, Sweden.
University of Örebro, Sweden.
University of Örebro, Sweden.
2015 (Engelska)Ingår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 56, nr 4, s. 487-492Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: The standard imaging procedure for a patient presenting with renal colic is unenhanced computed tomography (CT). The CT measured size has a close correlation to the estimated prognosis for spontaneous passage of a ureteral calculus. Size estimations of urinary calculi in CT images are still based on two-dimensional (2D) reformats. Purpose: To develop and validate a calculus oriented three-dimensional (3D) method for measuring the length and width of urinary calculi and to compare the calculus oriented measurements of the length and width with corresponding 2D measurements obtained in axial and coronal reformats. Material and Methods: Fifty unenhanced CT examinations demonstrating urinary calculi were included. A 3D symmetric segmentation algorithm was validated against reader size estimations. The calculus oriented size from the segmentation was then compared to the estimated size in axial and coronal 2D reformats. Results: The validation showed 0.1 +/- 0.7mm agreement against reference measure. There was a 0.4mm median bias for 3D estimated calculus length compared to 2D (P less than 0.001), but no significant bias for 3D width compared to 2D. Conclusion: The length of a calculus in axial and coronal reformats becomes underestimated compared to 3D if its orientation is not aligned to the image planes. Future studies aiming to correlate calculus size with patient outcome should use a calculus oriented size estimation.

Ort, förlag, år, upplaga, sidor
SAGE Publications (UK and US) , 2015. Vol. 56, nr 4, s. 487-492
Nyckelord [en]
Urinary; CT; ureter; kidney; segmentation; computer applications-3D
Nationell ämneskategori
Medicinsk bildbehandling
Identifikatorer
URN: urn:nbn:se:liu:diva-117365DOI: 10.1177/0284185114528490ISI: 000351594300015PubMedID: 24646626OAI: oai:DiVA.org:liu-117365DiVA, id: diva2:807868
Anmärkning

Funding Agencies|Forskningskommitten, Orebro County Council, Sweden

Tillgänglig från: 2015-04-24 Skapad: 2015-04-24 Senast uppdaterad: 2017-12-04

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed
Av organisationen
Centrum för medicinsk bildvetenskap och visualisering, CMIV
I samma tidskrift
Acta Radiologica
Medicinsk bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 47 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf