liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparing hepatic 2D and 3D magnetic resonance elastography methods in a clinical setting – Initial experiences
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Radiofysikavdelningen US. Wolfram MathCore AB, Linköping, Sweden.ORCID-id: 0000-0003-4630-6550
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Hälsouniversitetet. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping.
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Hälsouniversitetet. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping.ORCID-id: 0000-0003-3124-8044
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Radiofysikavdelningen US.ORCID-id: 0000-0002-6189-0807
Visa övriga samt affilieringar
2015 (Engelska)Ingår i: European Journal of Radiology Open, E-ISSN 2352-0477, Vol. 2, s. 66-70Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose

Continuous monitoring of liver fibrosis progression in patients is not feasible with the current diagnostic golden standard (needle biopsy). Recently, magnetic resonance elastography (MRE) has emerged as a promising method for such continuous monitoring. Since there are different MRE methods that could be used in a clinical setting there is a need to investigate whether measurements produced by these MRE methods are comparable. Hence, the purpose of this pilot study was to evaluate whether the measurements of the viscoelastic properties produced by 2D (stiffness) and 3D (elasticity and ‘Gabs,Elastic’) MRE are comparable.

Materials and methods

Seven patients with diffuse or suspect diffuse liver disease were examined in the same day with the two MRE methods. 2D MRE was performed using an acoustic passive transducer, with a 1.5 T GE 450 W MR system. 3D MRE was performed using an electromagnetic active transducer, with a 1.5 T Philips Achieva MR system. Finally, mean viscoelastic values were extracted from the same anatomical region for both methods by an experienced radiologist.

Results

Stiffness correlated well with the elasticity, R2 = 0.96 (P < 0.001; slope = 1.08, intercept = 0.61 kPa), as well as with ‘Gabs,ElasticR2 = 0.96 (P < 0.001; slope = 0.95, intercept = 0.28 kPa).

Conclusion

This pilot study shows that different MRE methods can produce comparable measurements of the viscoelastic properties of the liver. The existence of such comparable measurements is important, both from a clinical as well as a research perspective, since it allows for equipment-independent monitoring of disease progression.

Ort, förlag, år, upplaga, sidor
Elsevier, 2015. Vol. 2, s. 66-70
Nyckelord [en]
Liver; Rheology; Elastography; Fibrosis; MRE; MRI
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:liu:diva-119848DOI: 10.1016/j.ejro.2015.04.001OAI: oai:DiVA.org:liu-119848DiVA, id: diva2:827391
Tillgänglig från: 2015-06-26 Skapad: 2015-06-26 Senast uppdaterad: 2019-06-14Bibliografiskt granskad

Open Access i DiVA

fulltext(659 kB)190 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 659 kBChecksumma SHA-512
a359fcb35837e02f33ae7d5d12e92af81867711bee8fde9d7dd4f058203d84449138f6a6608c9f0e57f1355c0bb2d2488a3b46182e1e120f211da41b00921868
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Personposter BETA

Forsgren, MikaelNorén, BengtKihlberg, JohanDahlqvist Leinhard, OlofKechagias, StergiosLundberg, Peter

Sök vidare i DiVA

Av författaren/redaktören
Forsgren, MikaelNorén, BengtKihlberg, JohanDahlqvist Leinhard, OlofKechagias, StergiosLundberg, Peter
Av organisationen
Centrum för medicinsk bildvetenskap och visualisering, CMIVAvdelningen för radiologiska vetenskaperMedicinska fakultetenRadiofysikavdelningen USHälsouniversitetetRöntgenkliniken i LinköpingAvdelningen för kardiovaskulär medicinMagtarmmedicinska kliniken
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 190 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 446 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf