Chemical delivery array with millisecond neurotransmitter release
Linköping University, Department of Science and Technology, Physics and Electronics. Linköping University, Faculty of Science & Engineering.
Linköping University, Department of Science and Technology, Physics and Electronics. Linköping University, Faculty of Science & Engineering.
Linköping University, Department of Science and Technology, Physics and Electronics. Linköping University, Faculty of Science & Engineering.ORCID iD: 0000-0002-9845-446X
Linköping University, Department of Science and Technology, Physics and Electronics. Linköping University, Faculty of Science & Engineering.ORCID iD: 0000-0001-5154-0291
Show others and affiliations
2016 (English)In: Science Advances, ISSN 2375-2548, Vol. 2, no 11, article id e1601340Article in journal (Refereed) Published
Abstract [en]

Technologies that restore or augment dysfunctional neural signaling represent a promising route to deeper understanding and new therapies for neurological disorders. Because of the chemical specificity and subsecond signaling of the nervous system, these technologies should be able to release specific neurotransmitters at specific locations with millisecond resolution. We have previously demonstrated an organic electronic lateral electrophoresis technology capable of precise delivery of charged compounds, such as neurotransmitters. However, this technology, the organic electronic ion pump, has been limited to a single delivery point, or several simultaneously addressed outlets, with switch-on speeds of seconds. We report on a vertical neurotransmitter delivery device, configured as an array with individually controlled delivery points and a temporal resolution of 50 ms. This is achieved by supplementing lateral electrophoresis with a control electrode and an ion diode at each delivery point to allow addressing and limit leakage. By delivering local pulses of neurotransmitters with spatiotemporal dynamics approaching synaptic function, the high-speed delivery array promises unprecedented access to neural signaling and a path toward biochemically regulated neural prostheses.

Place, publisher, year, edition, pages
Washington: American Association for the Advancement of Science (A A A S) , 2016. Vol. 2, no 11, article id e1601340
National Category
Atom and Molecular Physics and Optics Computer Engineering Other Engineering and Technologies not elsewhere specified Biomedical Laboratory Science/Technology Signal Processing
Identifiers
URN: urn:nbn:se:liu:diva-133161DOI: 10.1126/sciadv.1601340ISI: 000391267800033PubMedID: 27847873OAI: oai:DiVA.org:liu-133161DiVA, id: diva2:1055206
Available from: 2016-12-12 Created: 2016-12-12 Last updated: 2018-01-13Bibliographically approved
In thesis
1. Organic electronics for precise delivery of neurotransmitters
Open this publication in new window or tab >>Organic electronics for precise delivery of neurotransmitters
2016 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Organic electronic materials, that is, carbon-based compounds that conduct electricity, have emerged as candidates for improving the interface between conventional electronics and biological systems. The softness of these materials matches the elasticity of biological tissue better than conventional electronic conductors, allowing better contact to tissue, and the mixed ionic-electronic conductivity can improve the signal transduction between electronic devices and electrically excitable cells. This improved communication between electronics and tissue can significantly enhance, for example, electrical stimulation for therapy and electrical recording for diagnostics.

The ionic conductivity of organic electronic materials makes it possible to achieve ion-specific ionic currents, where the current consists of migration of specific ions. These ions can be charged signalling substances, such as neurotransmitters, that can selectively activate or inhibit cells that contain receptors for these substances. This thesis describes the development of chemical delivery devices, where delivery is based on such ion-specific currents through ionically and electronically conducting polymers. Delivery is controlled by electrical signals, and allows release of controlled amounts of neurotransmitters, or other charged compounds, to micrometer-sized regions.

The aims of the thesis have been to improve spatial control and temporal resolution of chemical delivery, with the ultimate goal of selective interaction with individual cells, and to enable future therapies for disorders of the nervous system. Within the thesis, we show that delivery can alleviate pain through local delivery to specific regions of the spinal cord in an animal model of neuropathic pain, and that epilepsy-related signalling can be suppressed in vitro. We also integrate the delivery device with electrodes for sensing, to allow simultaneous electrical recording and delivery at the same position. Finally, we improve the delay from electrical signal to chemical delivery, approaching the time domain of synaptic signaling, and construct devices with several individually controlled release sites.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2016. p. 108
Series
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 1817
National Category
Textile, Rubber and Polymeric Materials Condensed Matter Physics Biomedical Laboratory Science/Technology Materials Chemistry Neurosciences
Identifiers
urn:nbn:se:liu:diva-133164 (URN)10.3384/diss.diva-133164 (DOI)978-91-7685-616-1 (ISBN)
Public defence
2017-01-11, Kåkenhus sal K3 (Önnesjösalen), Linköpings Universitet, Norrköping, 10:00 (English)
Opponent
Supervisors
Available from: 2016-12-12 Created: 2016-12-12 Last updated: 2019-10-29Bibliographically approved

Open Access in DiVA

fulltext(711 kB)163 downloads
File information
File name FULLTEXT01.pdfFile size 711 kBChecksum SHA-512
01294cb5f246ae6ab79b56d43999c20951d79bfd49441a75e1d7deaee8bad087294214bdb2399627efaac578308460ce7bbfc18840e248e79a73260490c40f30
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Jonsson, AmandaArbring Sjöström, TheresiaTybrandt, KlasBerggren, MagnusSimon, Daniel
By organisation
Physics and ElectronicsFaculty of Science & Engineering
Atom and Molecular Physics and OpticsComputer EngineeringOther Engineering and Technologies not elsewhere specifiedBiomedical Laboratory Science/TechnologySignal Processing

Search outside of DiVA

GoogleGoogle Scholar
Total: 163 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 1068 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf