An implantable pressure sensor for long-term wireless monitoring of cardiac function- first study in man
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Thorax-kärlkliniken i Östergötland.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Thorax-kärlkliniken i Östergötland.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
2016 (Engelska)Ingår i: Journal of Cardiovascular Diseases & Diagnosis, ISSN 2329-9517, Vol. 4, nr 4Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: Heart failure is a huge health problem. The possibility of long-term monitoring heart function more accurately in these patients has gained increasing interest. The primary aim of this study was to see if a wireless pressure sensor can be safely implanted to give accurate and reproducible long-term intracardiac pressure recordings. Another aim was to see if there are any adverse effects connected with the implant. A control group was included for comparison of clinical data.

Methods: Forty patients with heart failure, 31 scheduled for open heart surgery and 9 for transcatheter aortic valve replacement (TAVR) were included to test the safety and feasibility of the Titan™ pressure sensor. The patients were randomized to the implant or control group.

Findings: Initial sensor measurements showed very good correlation with reference pressure values from a fluid-filled catheter, and there was no need for calibration of the sensor. At the 6-month follow-up 11 patients had been wearing the implant for >1 year with a median time of 560 days. Ten of these had adequate sensor function. Compared to the control group there was no difference in adverse clinical events and the overall number of complications was low.

Conclusions: This first study in man on a new implantable wireless hemodynamic monitor showed favorable results regarding our primary endpoints; accuracy of recordings over time and safety profile. The technology has great potential for monitoring at home since it is easy to use in the out-patient setting.

Ort, förlag, år, upplaga, sidor
Omics Publishing Group , 2016. Vol. 4, nr 4
Nationell ämneskategori
Medicin och hälsovetenskap Klinisk medicin
Identifikatorer
URN: urn:nbn:se:liu:diva-135460DOI: 10.4172/2329-9517.1000252OAI: oai:DiVA.org:liu-135460DiVA, id: diva2:1081877
Tillgänglig från: 2017-03-15 Skapad: 2017-03-15 Senast uppdaterad: 2019-01-10

Open Access i DiVA

fulltext(807 kB)123 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 807 kBChecksumma SHA-512
abc2335bb1a29704ca9638f9d46a3b77f2e7ef81407c585f7ab8f3944adf1bb827a8abba85f147116ee15e27a23d870ed23ca74d37b74f9d0ed6b5848ab5392a
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Ahn, Henrik
Av organisationen
Avdelningen för kardiovaskulär medicinMedicinska fakultetenThorax-kärlkliniken i ÖstergötlandFysiologiska kliniken US
Medicin och hälsovetenskapKlinisk medicin

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 123 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 427 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf