liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
International Outcome Inventory for Hearing Aids: Data From a Large Swedish Quality Register Database
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Logopedi, Audiologi och Otorhinolaryngologi. Linköpings universitet, Medicinska fakulteten.
Royal Institute Technology, Sweden.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för neuro- och inflammationsvetenskap. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Sinnescentrum, Öron- näsa- och halskliniken US.ORCID-id: 0000-0001-8743-1636
2017 (Engelska)Ingår i: American Journal of Audiology, ISSN 1059-0889, E-ISSN 1558-9137, Vol. 26, nr 3, s. 443-450Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: The purpose of this study was to analyze a database of completed International Outcome Inventory for Hearing Aids (IOI-HA) questionnaires obtained from over 100,000 clients fitted with new hearing aids in Sweden during the period of 2012-2016. Mean IOI-HA total scores were correlated with degree of hearing loss, unilateral versus bilateral fitting, first-time versus return clients, gender, and variation among dispensing clinics. The correlations with expectations, service quality, and technical functioning of the hearing aids were also analyzed. Method: Questionnaires containing the 7 IOI-HA items as well as questions concerning some additional issues were mailed to clients 3-6 months after fitting of new hearing aids. The questionnaires were returned to and analyzed by an independent research institute. Results: More than 100 dispensing clinics nationwide take part in this project. A response rate of 52.6% resulted in 106,631 data sets after excluding incomplete questionnaires. Forty-six percent of the responders were women, and 54% were men. The largest difference in mean score (0.66) was found for the IOI-HA item "use" between return clients and first-time users. Women reported significantly higher (better) scores for the item "impact on others" compared with men. The bilaterally fitted subgroup reported significantly higher scores for all 7 items compared with the unilaterally fitted subgroup. Experienced users produced higher scores on benefit and satisfaction items, whereas first-time users gave higher scores for residual problems. No correlation was found between mean IOI-HA total score and average hearing threshold level (pure-tone average [ PTA]). Mean IOI-HA total scores were found to correlate significantly with perceived service quality of the dispensing center and with the technical functionality of the hearing aids. Conclusions: When comparing mean IOI-HA total scores from different studies or between groups, differences with regard to hearing aid experience, gender, and unilateral versus bilateral fitting have to be considered. No correlation was found between mean IOI-HA total score and degree of hearing loss in terms of PTA. Thus, PTA is not a reliable predictor of benefit and satisfaction of hearing aid provision as represented by the IOI-HA items. Identification of a specific lower fence in PTA for hearing aid candidacy is therefore to be avoided. Large differences were found in mean IOI-HA total scores related to different dispensing centers.

Ort, förlag, år, upplaga, sidor
AMER SPEECH-LANGUAGE-HEARING ASSOC , 2017. Vol. 26, nr 3, s. 443-450
Nationell ämneskategori
Annan hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-144000DOI: 10.1044/2017_AJA-16-0123ISI: 000418100300011PubMedID: 29049627OAI: oai:DiVA.org:liu-144000DiVA, id: diva2:1170208
Anmärkning

Funding Agencies|Swedish Association of Hard of Hearing People

Tillgänglig från: 2018-01-02 Skapad: 2018-01-02 Senast uppdaterad: 2019-01-15

Open Access i DiVA

fulltext(981 kB)183 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 981 kBChecksumma SHA-512
24de09030d1b7d72c47406c973f50cde709752adff777e24c29f792d62084c919430386b339108e9c840f942cf92b1436baecee5a168451328b469af283c486e
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Arlinger, StigÖberg, Marie
Av organisationen
Avdelningen för Logopedi, Audiologi och OtorhinolaryngologiMedicinska fakultetenAvdelningen för neuro- och inflammationsvetenskapÖron- näsa- och halskliniken US
I samma tidskrift
American Journal of Audiology
Annan hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 183 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 362 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf