Diagnostic Accuracy of a Machine-Learning Approach to Coronary Computed Tomographic Angiography-Based Fractional Flow Reserve Result From the MACHINE Consortium
Erasmus Univ, Netherlands.
Univ Ulsan, South Korea.
Inst Cardiol, Poland.
Med Univ South Carolina, SC 29425 USA.
Vise andre og tillknytning
2018 (engelsk)Inngår i: Circulation Cardiovascular Imaging, ISSN 1941-9651, E-ISSN 1942-0080, Vol. 11, nr 6, artikkel-id e007217Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Coronary computed tomographic angiography (CTA) is a reliable modality to detect coronary artery disease. However, CTA generally overestimates stenosis severity compared with invasive angiography, and angiographic stenosis does not necessarily imply hemodynamic relevance when fractional flow reserve (FFR) is used as reference. CTA-based FFR (CT-FFR), using computational fluid dynamics (CFD), improves the correlation with invasive FFR results but is computationally demanding. More recently, a new machine-learning (ML) CT-FFR algorithm has been developed based on a deep learning model, which can be performed on a regular workstation. In this large multicenter cohort, the diagnostic performance ML-based CT-FFR was compared with CTA and CFD-based CT-FFR for detection of functionally obstructive coronary artery disease. Methods and Results: At 5 centers in Europe, Asia, and the United States, 351 patients, including 525 vessels with invasive FFR comparison, were included. ML-based and CFD-based CT-FFR were performed on the CTA data, and diagnostic performance was evaluated using invasive FFR as reference. Correlation between ML-based and CFD-based CT-FFR was excellent (R=0.997). ML-based (area under curve, 0.84) and CFD-based CT-FFR (0.84) outperformed visual CTA (0.69; Pamp;lt;0.0001). On a per-vessel basis, diagnostic accuracy improved from 58% (95% confidence interval, 54%-63%) by CTA to 78% (75%-82%) by ML-based CT-FFR. The per-patient accuracy improved from 71% (66%-76%) by CTA to 85% (81%-89%) by adding ML-based CT-FFR as 62 of 85 (73%) false-positive CTA results could be correctly reclassified by adding ML-based CT-FFR. Conclusions: On-site CT-FFR based on ML improves the performance of CTA by correctly reclassifying hemodynamically nonsignificant stenosis and performs equally well as CFD-based CT-FFR.

sted, utgiver, år, opplag, sider
LIPPINCOTT WILLIAMS & WILKINS , 2018. Vol. 11, nr 6, artikkel-id e007217
Emneord [en]
area under curve; computed tomography angiography; coronary artery disease; hemodynamics; machine learning
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-149477DOI: 10.1161/CIRCIMAGING.117.007217ISI: 000435564000003PubMedID: 29914866OAI: oai:DiVA.org:liu-149477DiVA, id: diva2:1231076
Tilgjengelig fra: 2018-07-05 Laget: 2018-07-05 Sist oppdatert: 2019-05-02

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

De Geer, Jakob

Søk i DiVA

Av forfatter/redaktør
De Geer, JakobPersson, Anders
Av organisasjonen
I samme tidsskrift
Circulation Cardiovascular Imaging

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 164 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf