liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evaluation of clinical outcomes following implantation of a sub-2-mm hydrophilic acrylic MICS intraocular lens
University Eye Hospital Bochum, Bochum, Germany.
University Eye Hospital Bochum, Bochum, Germany.
Centre Ophtalmologique Iridis, Albi, France.
Ospedale di Bassano del Grappa Bassano del Grappa, Bassano del Grappa, Italy.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: International ophtalmology, ISSN 0165-5701, E-ISSN 1573-2630, Vol. 39, nr 5, s. 1043-1054Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PURPOSE: To evaluate clinical outcomes following sub-2-mm microincision cataract surgery (MICS) and intraocular lens (IOL) implantation.

SETTING: Five EU clinical sites.

DESIGN: Prospective, multicenter, open-label, single-arm, non-randomized.

METHODS: Preoperative assessment involved visual acuity (VA), intraocular pressure and biometry measurements. 1.4-mm wound-assisted or 1.8-mm MICS was performed. Follow-up visits were made 1 day, 1-2 weeks, 1-2 and 4-6 months after surgery. The incision size, corrected distance VA (CDVA), uncorrected distance VA, manifest refraction spherical equivalent (MRSE), refraction predictability/stability and IOL decentration were assessed. At 12-, 18-, and 24-month, long-term centration, posterior capsular opacification (PCO) and Nd:YAG capsulotomy rates were investigated.

RESULTS: A total of 103 eyes were implanted with the study IOL (INCISE, Bausch & Lomb), 96 of which were included in visual outcome analysis. A mean 6-month CDVA of - 0.02 logMAR (20/20 + 1) was observed and 75 eyes (79.8%) and 93 eyes (98.3%) achieved a visual acuity of at least 20/20 or 20/40. Mean MRSE was - 0.20 ± 0.60 D. Mean absolute predictive error was 0.44 ± 0.36 D, with 90.4% within 1.00 D of target. Mean total decentration was 0.35 ± 0.36 mm at 6 months and 0.32 ± 0.14 mm at 24 months (p > 0.05). 24-month evaluation of posterior capsular opacification score was 0.03 for the central area. A Nd:YAG rate of 3.4% was observed at 24 months.

CONCLUSIONS: The new MICS IOL provided excellent visual outcomes and was safe and effective for the sub-2-mm procedure. The MICS IOL demonstrated long-term centration, stability and a low rate of PCO development.

Ort, förlag, år, upplaga, sidor
Springer Netherlands, 2019. Vol. 39, nr 5, s. 1043-1054
Nyckelord [en]
Implantation, Intraocular lens, Microincision cataract surgery
Nationell ämneskategori
Oftalmologi
Identifikatorer
URN: urn:nbn:se:liu:diva-153462DOI: 10.1007/s10792-018-0905-3ISI: 000467649400009PubMedID: 29654574Scopus ID: 2-s2.0-85045259988OAI: oai:DiVA.org:liu-153462DiVA, id: diva2:1272631
Tillgänglig från: 2018-12-19 Skapad: 2018-12-19 Senast uppdaterad: 2019-06-22Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Personposter BETA

Johansson, Björn

Sök vidare i DiVA

Av författaren/redaktören
Johansson, Björn
Av organisationen
Avdelningen för neuro- och inflammationsvetenskapMedicinska fakultetenÖgonkliniken US/LiM
I samma tidskrift
International ophtalmology
Oftalmologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 57 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf