Validation of pressure drop assessment using 4D flow MRI-based turbulence production in various shapes of aortic stenoses
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, Republic of Korea.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Hjärt- och Medicincentrum, Thorax-kärlkliniken i Östergötland. Department of Cardiothoracic Surgery, Oslo University Hospital, Rikshospitalet, Oslo, Norway.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.ORCID-id: 0000-0003-1395-8296
2019 (Engelska)Ingår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 81, nr 2, s. 893-906Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose

To validate pressure drop measurements using 4D flow MRI‐based turbulence production in various shapes of stenotic stenoses.

Methods

In vitro flow phantoms with seven different 3D‐printed aortic valve geometries were constructed and scanned with 4D flow MRI with six‐directional flow encoding (ICOSA6). The pressure drop through the valve was non‐invasively predicted based on the simplified Bernoulli, the extended Bernoulli, the turbulence production, and the shear‐scaling methods. Linear regression and agreement of the predictions with invasively measured pressure drop were analyzed.

Results

All pressure drop predictions using 4D Flow MRI were linearly correlated to the true pressure drop but resulted in different regression slopes. The regression slope and 95% limits of agreement for the simplified Bernoulli method were 1.35 and 11.99 ± 21.72 mm Hg. The regression slope and 95% limits of agreement for the extended Bernoulli method were 1.02 and 0.74 ± 8.48 mm Hg. The regression slope and 95% limits of agreement for the turbulence production method were 0.89 and 0.96 ± 8.01 mm Hg. The shear‐scaling method presented good correlation with an invasively measured pressure drop, but the regression slope varied between 0.36 and 1.00 depending on the shear‐scaling coefficient.

Conclusion

The pressure drop assessment based on the turbulence production method agrees well with the extended Bernoulli method and invasively measured pressure drop in various shapes of the aortic valve. Turbulence‐based pressure drop estimation can, as a complement to the conventional Bernoulli method, play a role in the assessment of valve diseases.

Ort, förlag, år, upplaga, sidor
Wiley-Blackwell, 2019. Vol. 81, nr 2, s. 893-906
Nyckelord [en]
4D Flow MRI; 4D PC-MRI; Reynolds stress; magnetic resonance imaging; phase contrast MRI; pressure drop; turbulence
Nationell ämneskategori
Fysiologi
Identifikatorer
URN: urn:nbn:se:liu:diva-156013DOI: 10.1002/mrm.27437ISI: 000462086300015PubMedID: 30252155Scopus ID: 2-s2.0-85053757763OAI: oai:DiVA.org:liu-156013DiVA, id: diva2:1301616
Tillgänglig från: 2019-04-02 Skapad: 2019-04-02 Senast uppdaterad: 2020-01-14Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Personposter BETA

Escobar Kvitting, John-Peder

Sök vidare i DiVA

Av författaren/redaktören
Ha, HojinEscobar Kvitting, John-PederDyverfeldt, PetterEbbers, Tino
Av organisationen
Avdelningen för kardiovaskulär medicinMedicinska fakultetenCentrum för medicinsk bildvetenskap och visualisering, CMIVThorax-kärlkliniken i ÖstergötlandFysiologiska kliniken US
I samma tidskrift
Magnetic Resonance in Medicine
Fysiologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 67 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf