Design and performance of a coarse media, high hydraulic load polishing wetland for steel industry wastewater
HUCE, Vietnam.
VNU Univ Sci, Vietnam.
Linköpings universitet, Institutionen för fysik, kemi och biologi, Biologi. Linköpings universitet, Tekniska fakulteten.ORCID-id: 0000-0002-0722-6083
HUMG, Vietnam.
Vise andre og tillknytning
2019 (engelsk)Inngår i: Water Science and Technology, ISSN 0273-1223, E-ISSN 1996-9732, Vol. 80, nr 1, s. 59-66Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper presents the design of a constructed wetland (CW) system in an area with limited land availability, resulting in high hydraulic loads. The CW was constructed to act as a buffering/polishing step after stabilization ponds for steel industry wastewater post-treatment. A pilot test with two different filter media (50-100 mm vs 40-60 mm diameter) indicated that a flow rate increase from 49.5 m(3)/h to 122.4 m(3)/h would lead to a head loss increase from 2.9 cm to 8.7 cm, and more than double that for the finer gravel. This was substantially higher than the calculated theoretical values, though the relation with flow rate was similar. Four full scale wetland cells (CW1, CW2, CW3 and CW4) were constructed using the coarser gravel. A design value of total head loss of 1.01 m over the total system length, with a design flow of 36,000 m(3)/day, was expected based on pilot test results. During the first operation year (September 2017 to July 2018), the pond-CW system has received wastewater already meeting required discharge standards. The effluent from the CWs had consistently lower concentrations of all measured variables, and met the predicted values for biochemical oxygen demand (BOD5), total nitrogen (TN) and NH4+-N. Highest removal efficiencies were achieved for NH4+-N (amp;gt; 90%), Mn (amp;gt; 60%) and Fe (45%) with removal efficiencies for TN (14%), BOD5 and chemical oxygen demand (COD) (around 30%). Concentrations of phenol, CN- and Cr6+ were below 10, 4 and 3 mu g/l, respectively, in in- and outflows. An appreciated benefit of the wetland was the green element in the industrial landscape.

sted, utgiver, år, opplag, sider
IWA PUBLISHING , 2019. Vol. 80, nr 1, s. 59-66
Emneord [en]
filter media; free water surface; head loss estimate; horizontal subsurface flow
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-161209DOI: 10.2166/wst.2019.244ISI: 000486895000006PubMedID: 31461422OAI: oai:DiVA.org:liu-161209DiVA, id: diva2:1365660
Tilgjengelig fra: 2019-10-25 Laget: 2019-10-25 Sist oppdatert: 2019-10-25

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Tonderski, Karin
Av organisasjonen
I samme tidsskrift
Water Science and Technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 18 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf