Determination of insulin autoantibodies using surface plasmon resonance: A screening study of newly diagnosed type 1 diabetes patients
Linköpings universitet, Institutionen för fysik, kemi och biologi, Tillämpad Fysik. Linköpings universitet, Tekniska högskolan.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Pediatrik. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Cellbiologi. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Pediatrik. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Barn- och kvinnocentrum, Barn- och ungdomskliniken i Linköping.
Visa övriga samt affilieringar
2008 (Engelska)Manuskript (preprint) (Övrigt vetenskapligt)
Abstract [en]

We have investigated the screening potential of a surface plasmon resonance (SPR)-based indirectcompetitive immunoassay for quantification of insulin autoantibodies (IAA) in sera from childrennewly diagnosed with type 1 diabetes (T1D), using a radioimmunoassay (RIA) as reference technique.The two methods agreed well with respect to sample classification of 54 sera from newly diagnosedT1D children and 32 reference sera from non-diabetic children. Interestingly, five samples from newlydiagnosed T1D patients classified as IAA-negative according to RIA were IAA-positive with the SPRbasedassay, suggesting that the SPR-based assay might provide a higher sensitivity than the referenceRIA. However, 14 percent of the analyzed samples (five samples from non-diabetics and seven fromnewly diagnosed T1D patients) gave rise to anomalously high and easily distinguishable responses withthe SPR-based method, precluding IAA-quantification. A considerable part of the paper is devoted to adiscussion of possible causes of these anomalous responses. They were not due to temporary changesin the status of the patients, such as infections at the time of sampling, and also not related tocomplement activation. It is speculated whether a plausible explanation should instead be sought in theexistence of anti-idiotypic antibodies to IAA.

Ort, förlag, år, upplaga, sidor
2008.
Nationell ämneskategori
Kemi
Identifikatorer
URN: urn:nbn:se:liu:diva-12470OAI: oai:DiVA.org:liu-12470DiVA, id: diva2:182
Tillgänglig från: 2008-09-06 Skapad: 2008-09-06 Senast uppdaterad: 2015-10-05Bibliografiskt granskad
Ingår i avhandling
1. Interaction Studies in Complex Fluids with Optical Biosensors
Öppna denna publikation i ny flik eller fönster >>Interaction Studies in Complex Fluids with Optical Biosensors
2008 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

In this thesis interactions in complex fluids, such as serum and meat juice, were analysed with optical biosensor techniques.

Panels of lectins immobilised on gold surfaces were used for investigation of differences in protein glycosylation pattern in sera and meat juices between various species. The present panel was also used for investigation of global glycosylation changes of serum proteins in type 1 diabetes patients. Biorecognition was evaluated with null ellipsometry and scanning ellipsometry combined with multivariate data analysis techniques (MVDA). Principal component analysis (PCA) showed that the lectin panel enabled discrimination between sera from the different species as well as for the different meat juices. The results also indicate that there is a measurable global alteration in glycosylation pattern of serum proteins in type 1 diabetic patients compared to healthy subjects. Using an artificial neuronal net (ANN), it was also possible to correctly categorise unknown serum samples into their respective class or group. The analytical potential of combining information from lectin panels with multivariate data analysis was thereby demonstrated.

Also, a sensitive and specific method based on surface plasmon resonance (SPR) for detection of insulin autoantibodies (IAA) in serum samples from individuals at high risk of developing type 1 diabetes (T1D) has been developed. When measuring trace molecules, such as autoantibodies, in undiluted sera with label-free techniques like SPR, non-specific adsorption of matrix proteins to the sensor surface is often a problem, since it causes a signal that masks the analyte response. The developed method is an indirect competitive immunoassay designed to overcome these problems. Today, IAA is mainly measured in radio immunoassays (RIAs), which are time consuming and require radioactively labelled antigen. With our SPR-based immunoassay the overall assay time is reduced by a factor of >100 (from 4 days to 50 min), while sensitivity is maintained at a level comparable to that offered by RIA. Finally, the assay was used in a screening study of newly diagnosed type 1 diabetes patients and non-diabetic subjects.

Ort, förlag, år, upplaga, sidor
Linköping: Linköping University Electronic Press, 2008. s. 70
Serie
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 1195
Nyckelord
Type 1 diabetes, Insulin, Lectin panel, Ellipsometry, Meat juice, Serum proteins
Nationell ämneskategori
Kemi
Identifikatorer
urn:nbn:se:liu:diva-14694 (URN)978-91-7394-852-5 (ISBN)
Disputation
2008-09-19, Planck, Fysikhuset, Campus Norrköping, Linköpings universitet, Linköping, 10:15 (Engelska)
Opponent
Handledare
Tillgänglig från: 2008-09-26 Skapad: 2008-09-19 Senast uppdaterad: 2009-04-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Link to Ph.D. Thesis

Personposter BETA

Carlsson, JennyGullstrand, CamillaWestermark, GunillaLudvigsson, JohnnyEnander, KarinLiedberg, Bo

Sök vidare i DiVA

Av författaren/redaktören
Carlsson, JennyGullstrand, CamillaWestermark, GunillaLudvigsson, JohnnyEnander, KarinLiedberg, Bo
Av organisationen
Tillämpad FysikTekniska högskolanPediatrikHälsouniversitetetCellbiologiBarn- och ungdomskliniken i LinköpingSensorvetenskap och Molekylfysik
Kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 365 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf