Piezoelectric Coatings on Implants: Sample preparation and construction of test-equipment for in vitro experiments
Linköpings universitet, Institutionen för fysik, kemi och biologi.
2005 (Engelska)Självständigt arbete på grundnivå (yrkesexamen), 20 poäng / 30 hpStudentuppsats
Abstract [en]

Implants are commonly used for orthopaedic and dental applications. There is however a problem with implants; they have a tendency to get loose after 10-15 years of usage. Bone that is not used will get weaker; this can be concluded from studies of people being immobilised or in microgravity. When an implant is put into bone, the surrounding bone does not experience any deformation and it will resorb. This is called stress shielding. Finally the implant will get loose. To avoid this problem we want to give electrical stimulation to the bone surrounding the implant. Electricity has been used before to stimulate bone, and it has been shown that immobilised bone can almost be maintained by using electric stimulation.

Piezoelectricity is a property of certain materials that make them generate electricity when they are deformed. When an implant is coated with a piezoelectric material, electrical stimulation can be achieved for the surrounding bone that is stress shielded.

In this diploma work, a test-equipment is built to stimulate cells. Cells will be grown on a piezoelectric plate that is bent by the test-equipment. Thus, the cells will be stimulated by both mechanical stress and electric potential since the piezoelectric material generates electricity when it is deformed. Piezoelectric samples and culture wells suitable for bending applications are prepared and tested in the equipment.

Some initial cell growth experiments have been performed to see that the material is suitable for cell growth.

Ort, förlag, år, upplaga, sidor
Institutionen för fysik, kemi och biologi , 2005. , s. 81
Nyckelord [en]
Piezoelectricity, Stress shielding, Bone growth, Implant, Coating
Nationell ämneskategori
Biofysik
Identifikatorer
URN: urn:nbn:se:liu:diva-4544ISRN: LITH-IFM-EX--05/1408—SEOAI: oai:DiVA.org:liu-4544DiVA, id: diva2:20640
Uppsök
teknik
Handledare
Examinatorer
Tillgänglig från: 2005-11-16 Skapad: 2005-11-16

Open Access i DiVA

fulltext(2115 kB)1304 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2115 kBChecksumma SHA-1
72f181c4166ffddb503c517a5649fdae72c4f74ff1653a1673d43cb2f3da57831a53d176
Typ fulltextMimetyp application/pdf

Av organisationen
Institutionen för fysik, kemi och biologi
Biofysik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 1304 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 2614 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf