liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Scientific  instrument for a controlled choice of optimal photon energy in intra-oral radiography
Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen. (Landstinget i Östergötland)
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen. Linköpings universitet, Hälsouniversitetet.ORCID-id: 0000-0003-3352-8330
n/a.
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Hälsouniversitetet.ORCID-id: 0000-0003-0209-498X
1998 (Engelska)Ingår i: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 80, nr 1, s. 321-325Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Basic performance parameters are defined and analysed in order to optimise physical image quality in relation to the energy imparted to the patient in dental radiology. Air cavities were embedded in well-defined multimaterial, hard tissue phantoms to represent various objects in dento-maxillo-facial examinations. Basic performance parameters were: object contrast (C), energy imparted (_) to the patient, signal-to-noise ration (SNR), C2/_ (film) and (SNR)2/_ (digital imaging system) as functions of HVL (half-value layer), used to describe the photon energy spectrum. For the film receptor, the performance index C2/_ is maximum (optimal) at HVL values of 1.5-1.7 mm Al in the simulated Incisive, Premolar and Molar examinations. Other imaging tasks (examinations), not simulated here, may require other optimal HVL. For the digital imaging system (Digora) the performance index (SNR)2/_, theoretically calculated, indicates that a lower value of HVL is optimal than with film as receptor. However, due to the limited number of bits (8 bits) in the analogue to digital converter (ADC) contrast resolution is degraded and calls for use of higher photon energies (HVL). Customised optimisations with proper concern for patient category, type of examination, diagnostic task is the ultimate goal of this work. The conclusions stated above give some general advice on the appropriate choice of photon energy spectrum (HVL). In particular situations, it may be necessary to use more dose demanding kV settings (lower HVL) in order to get sufficient image quality for the diagnostic task.

Ort, förlag, år, upplaga, sidor
1998. Vol. 80, nr 1, s. 321-325
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-20929OAI: oai:DiVA.org:liu-20929DiVA, id: diva2:236829
Tillgänglig från: 2009-09-25 Skapad: 2009-09-25 Senast uppdaterad: 2017-12-13

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Link to Journal

Personposter BETA

Sandborg, MichaelAlm Carlsson, Gudrun

Sök vidare i DiVA

Av författaren/redaktören
Sandborg, MichaelAlm Carlsson, Gudrun
Av organisationen
RadiofysikavdelningenMedicinsk radiofysikCentrum för medicinsk bildvetenskap och visualisering, CMIVHälsouniversitetet
I samma tidskrift
Radiation Protection Dosimetry
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 105 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf