Improving Temporal Fidelity in k-t BLAST MRI Reconstruction
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik. Linköpings universitet, Tekniska högskolan. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
Linköpings universitet, Institutionen för medicinsk teknik, Centrum för medicinsk bildvetenskap och visualisering. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
Linköpings universitet, Institutionen för medicinsk teknik, Centrum för medicinsk bildvetenskap och visualisering. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Thorax-kärlkliniken.
Visa övriga samt affilieringar
2007 (Engelska)Ingår i: Medical Image Computing and Computer-Assisted Intervention – MICCAI 2007: 10th International Conference, Brisbane, Australia, October 29 - November 2, 2007, Proceedings, Part II / [ed] Ayache, N; Ourdelin, S; Maeder, A, Springer Berlin/Heidelberg, 2007, s. 385-392Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Studies of myocardial motion using magnetic resonance imaging usually require multiple breath holds and several methods have been proposed in order to reduce the scan time. Rapid imaging using k-t BLAST has gained much attention with its high reduction factors and image quality. Temporal smoothing, however, may reduce the accuracy when assessing cardiac function. In the present work, a modified reconstruction filter is proposed, that preserves more of the high temporal frequencies. Artificial decimation of a fully sampled data set was used to evaluate the reconstruction filter. Compared to the conventional k-t BLAST reconstruction, the modified filter produced images with sharper temporal delineation of the myocardial walls.  Quantitative analysis by means of regional velocity estimation showed that the modified reconstruction filter produced more accurate velocity estimations.

Ort, förlag, år, upplaga, sidor
Springer Berlin/Heidelberg, 2007. s. 385-392
Serie
Lecture Notes in Computer Science, ISSN 0302-9743, E-ISSN 1611-3349 ; 4792
Nationell ämneskategori
Medicinsk bildbehandling
Identifikatorer
URN: urn:nbn:se:liu:diva-21764DOI: 10.1007/978-3-540-75759-7_47ISI: 000250917700047ISBN: 978-3-540-75758-0 (tryckt)ISBN: 978-3-540-75759-7 (tryckt)OAI: oai:DiVA.org:liu-21764DiVA, id: diva2:241662
Konferens
MICCAI 2007, 10th International Conference, Brisbane, Australia, October 29 - November 2, 2007
Tillgänglig från: 2009-10-05 Skapad: 2009-10-05 Senast uppdaterad: 2018-02-09Bibliografiskt granskad
Ingår i avhandling
1. Multidimensional MRI  of Myocardial Dynamics: Acquisition, Reconstruction and Visualization
Öppna denna publikation i ny flik eller fönster >>Multidimensional MRI  of Myocardial Dynamics: Acquisition, Reconstruction and Visualization
2009 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Methods for measuring deformation and motion of the human heart in-vivo are crucial in the assessment of cardiac function. Applications ranging from basic physiological research, through early detection of disease to follow-up studies, all rely on the quality of the measurements of heart dynamics. This thesis presents new improved magnetic resonance imaging methods for acquisition, image reconstruction and visualization of cardiac motion and deformation.As the heart moves and changes shape during the acquisition, synchronization to the heart dynamics is necessary. Here, a method to resolve not only the cardiac cycle but also the respiratory cycle is presented. Combined with volumetric imaging, this produces a five-dimensional data set with two cyclic temporal dimensions. This type of data reveals unique physiological information, such as interventricular coupling in the heart in different phases of the respiratory cycle.The acquisition can also be sensitized to motion, measuring not only the magnitude of the magnetization but also a signal proportional to local velocity or displacement. This allows for quantification of the motion which is especially suitable for functional study of the cardiac deformation. In this work, an evaluation of the influence of several factors on the signal-to-noise ratio is presented for in-vivo displacement encoded imaging. Additionally, an extension of the method to acquire multiple displacement encoded slices in a single breath hold is also presented.Magnetic resonance imaging is usually associated with long scan times, and many methods exist to shorten the acquisition time while maintaining acceptable image quality. One class of such methods involves acquiring only a sparse subset of k-space. A special reconstruction is then necessary in order to obtain an artifact-free image. One family of these reconstruction techniques tailored for dynamic imaging is the k-t BLAST approach, which incorporates data-driven prior knowledge to suppress aliasing artifacts that otherwise occur with the sparse sampling. In this work, an extension of the original k-t BLAST method to two temporal dimensions is presented and applied to data acquired with full coverage of the cardio-respiratory cycles. Using this technique, termed k-t2 BLAST, simultaneous reduction of scan time and improved spatial resolution is demonstrated. Further, the loss of temporal fidelity when using the k-t BLAST approach is investigated, and an improved reconstruction is proposed for the application of cardiac function analysis.Visualization is a crucial part of the imaging chain. Scalar data, such as regular anatomical images, are straightforward to display. Myocardial strain and strain-rate, however, are tensor quantities which do not lend themselves to direct visualization. The problem of visualizing the tensor field is approached in this work by combining a local visualization that displays all degrees of freedom for a single tensor with an overview visualization using a scalar field representation of the complete tensor field. The scalar field is obtained by iterated adaptive filtering of a noise field, creating a continuous geometrical representation of the myocardial strain-rate tensor field.The results of the work presented in this thesis provide opportunities for improved imaging of myocardial function, in all areas of the imaging chain; acquisition, reconstruction and visualization.

 

Ort, förlag, år, upplaga, sidor
Linköping: Linköping University Electronic Press, 2009. s. 71
Serie
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 1287
Nyckelord
MRI, Cardiac motion, myocardial dynamics, strain, tensor, deformation, DENSE, k-t BLAST
Nationell ämneskategori
Medicinsk laboratorie- och mätteknik
Identifikatorer
urn:nbn:se:liu:diva-51489 (URN)978-91-7393-494-7 (ISBN)
Disputation
2009-12-18, Conrad, Campus US, Linköpings Universitet, Linköping, 09:15 (Engelska)
Opponent
Handledare
Tillgänglig från: 2009-11-30 Skapad: 2009-11-04 Senast uppdaterad: 2013-08-28Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextLink to Ph.D. Thesisfind book in another country/hitta boken i ett svenskt bibliotek

Personposter BETA

Sigfridsson, AndreasAndersson, MatsWigström, LarsKvitting, John-Peder EscobarKnutsson, Hans

Sök vidare i DiVA

Av författaren/redaktören
Sigfridsson, AndreasAndersson, MatsWigström, LarsKvitting, John-Peder EscobarKnutsson, Hans
Av organisationen
Centrum för medicinsk bildvetenskap och visualisering, CMIVKlinisk fysiologiInstitutionen för medicinsk teknikHälsouniversitetetFysiologiska kliniken USMedicinsk informatikTekniska högskolanCentrum för medicinsk bildvetenskap och visualiseringThorax-kärlkliniken
Medicinsk bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 722 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf