liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Limited effectiveness of intraoperative autotransfusion in major back surgery
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Anestesiologi. Östergötlands Läns Landsting, MKC - Medicin och kirurgicentrum, Anestesi.
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för nervsystem och rörelseorgan, Ortopedi och Idrottsmedicin.
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Anestesiologi. Östergötlands Läns Landsting, MKC - Medicin och kirurgicentrum, Anestesi.
2001 (engelsk)Inngår i: European Journal of Anaesthesiology, ISSN 0265-0215, E-ISSN 1365-2346, Vol. 18, nr 12, s. 823-828Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background and objective: The efficiency of intraoperative autotransfusion in scoliosis surgery is poorly known but needs to be evaluated, not least because of the large blood losses in these patients. This is a retrospective analysis of transfusion requirements of 43 such patients. Methods: Records from 43 patients were studied. During surgery, the shed blood was salvaged and washed in an autotransfusion device (AT1000 Auto-transfusion Unit«) and a suspension of red cells was reinfused. Results: Fifty-eight per cent of the intraoperative blood loss was salvaged. The total blood loss during the patients' hospital stay was calculated from the haemoglobin balance, 24% of this loss was salvaged by the device. Moreover, 36 of the patients needed allogeneic blood transfusion. Conclusion: The efficiency of the autotransfusion device was relatively low in relation to the total extravasation, mainly because the postoperative blood loss is substantial.

sted, utgiver, år, opplag, sider
2001. Vol. 18, nr 12, s. 823-828
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-26730DOI: 10.1046/j.1365-2346.2001.01005.xLokal ID: 11325OAI: oai:DiVA.org:liu-26730DiVA, id: diva2:247280
Tilgjengelig fra: 2009-10-08 Laget: 2009-10-08 Sist oppdatert: 2017-12-13

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Aaro, StigLisander, Björn

Søk i DiVA

Av forfatter/redaktør
Aaro, StigLisander, Björn
Av organisasjonen
I samme tidsskrift
European Journal of Anaesthesiology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 772 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf