Anatomic M-mode echocardiography: a new approach to assess regional myocardial function - A comparative in vivo and in vitro study of both fundamental and second harmonic imaging modes
Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet.
Visa övriga samt affilieringar
1999 (Engelska)Ingår i: Journal of the American Society of Echocardiography, ISSN 0894-7317, E-ISSN 1097-6795, Vol. 12, nr 5, s. 300-307Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objective: To evaluate the accuracy of anatomic M-mode echocardiography (AMM).

Methods: Eight phantoms were rotated on a device at different insonation depths (IDs) in a water beaker. They were insonated with different transducer frequencies in fundamental imaging (FI) and second harmonic imaging (SHI), and the diameters were assessed with conventional M-mode echocardiography (CMM) and AMM with the applied angle correction (AC) after rotation. In addition, left ventricular wall dimensions were measured with CMM and AMM in FI and SHI in 10 volunteers.

Results: AC had the greatest effect on the measurement error in AMM followed by ID (AC: R2 = 0.295, ID: R2 = 0.268; P < .0001). SHI improved the accuracy, and a difference no longer existed between CMM and AMM with an AC up to 60 degrees. In vivo the limit of agreement between AMM and CMM was -1.7 to +1.8 mm in SHI.

Conclusion: Within its limitations (AC < 60 degrees; ID < 20 cm), AMM could be a robust tool in clinical practice.

Ort, förlag, år, upplaga, sidor
1999. Vol. 12, nr 5, s. 300-307
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-26981DOI: 10.1016/S0894-7317(99)70050-7Lokalt ID: 11616OAI: oai:DiVA.org:liu-26981DiVA, id: diva2:247532
Tillgänglig från: 2009-10-08 Skapad: 2009-10-08 Senast uppdaterad: 2017-12-13
Ingår i avhandling
1. Quantification of cardiovascular flow and motion: aspects of regional myocardial function and flow patterns in the aortic root and the aorta
Öppna denna publikation i ny flik eller fönster >>Quantification of cardiovascular flow and motion: aspects of regional myocardial function and flow patterns in the aortic root and the aorta
2004 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Quantification of cardiovascular flow and motion is essential in the diagnosis, treatment and follow-up of cardiovascular disease. The accuracy and quantification of many imaging methods used in this field have important shortfalls, however, that result from limitations in spatial and temporal dimensions. Improvement in application of these methods requires an in-depth understanding of the technical and perceptual aspects that contribute to errors in their use.

Visual assessment of echocardiographic images for asynchrony in regional myocardial motion during systolic contraction is an example of the need for better definition of limitations. The discernible delay in wall motion improved from 89 ms to 71 ms by allowing side-by-side comparison to normal motion. Clinically important delays are almost certainly missed with current "eyeballing" methods. Different and more quantitative approaches to this problem have been developed. Anatomic M-mode (AMM) assesses motion along an arbitrary line within a two-dimensional (2D) image, and was demonstrably robust in the clinical setting when used with second harmonic imaging at a depth less than 20 cm and with angle correction ofless than 60°. Doppler myocardial (DMI) imaging and strain rate imaging (SRI) were also shown to reliably demonstrate the effects of inotropic stimulation, total and severe ischemia on asynchrony in a closed chest pig model. Quantification of the changes induced by inotropy and total ischemia was possible with both methods, but the effects of stunning were not. Regional myocardial function and cardiovascular flow can also be assessed with time-resolved, three-directional, three-dimensional (3D) velocity data acquired using phase contrast magnetic resonance imaging (PC-MRI). This multidimensional data demonstrated longitudinal velocity gradients along all four walls of the left ventricle, with miuirnal apical longitudinal motion. The 3D velocity vector from single points in the ventricular wall shows that the motion over the cardiac cycle is complex in all dimensions. The flow patterns in the aortic root were also studied using time-resolved 3D PC-MRI in normal volunteers and patients who had undergone aortic-valve sparing surgery using straight Dacron grafts. In normals, vortices appeared in the sinuses of Valsalva in late systole, increased in size with the deceleration of aortic outflow and moved together as the valve closed in early diastole. These normal flow structures have never before been demonstrated in three dimensions in man. In the postoperative patients, lacking both sinuses and sinotubular junction, vortices were not observed.

Many imaging methods can be improved by a critical definition of the limits oftheir reliability. This can prompt the modifications and new methods which allow us to move beyond the original shortcomings and contribute new knowledge regarding the pathophysiology of cardiovascular disease.

Ort, förlag, år, upplaga, sidor
Linköping: Linköpings universitet, 2004. s. 63
Serie
Linköping University Medical Dissertations, ISSN 0345-0082 ; 832
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
urn:nbn:se:liu:diva-24209 (URN)3803 (Lokalt ID)91-7373-804-2 (ISBN)3803 (Arkivnummer)3803 (OAI)
Disputation
2004-02-20, Elsa Brändströmssalen, Universitetssjukhuset, Linköping, 13:00 (Svenska)
Opponent
Tillgänglig från: 2009-10-07 Skapad: 2009-10-07 Senast uppdaterad: 2012-10-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Escobar Kvitting, John-PederWranne, Bengt

Sök vidare i DiVA

Av författaren/redaktören
Escobar Kvitting, John-PederWranne, Bengt
Av organisationen
Klinisk fysiologiHälsouniversitetet
I samma tidskrift
Journal of the American Society of Echocardiography
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 92 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf