liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Computed tomographic colonography: Comparison of two workstations
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiologi.
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiologi. Östergötlands Läns Landsting, Bildmedicinskt centrum, Avdelningen för radiologi US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.ORCID-id: 0000-0002-9446-6981
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiologi. Östergötlands Läns Landsting, Bildmedicinskt centrum, Avdelningen för radiologi US.
Visa övriga samt affilieringar
2005 (Engelska)Ingår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 46, nr 7, s. 671-678Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: To compare two commercially available computed tomography (CT) colonography systems with respect to interobserver variability, the influence of level of expertise, and the gradual reduction of reviewing time for each system. Material and Methods: Two residents and two radiologists using Siemens CTAPP Colography software and Viatronix V3DColon software reviewed supine and prone CT acquisitions from 24 patients in a primary 3D endoluminal view. The observers graded each case with respect to technical quality and diagnostic value, assessed the presence of pathology, and indicated the time spent on the viewing. Results: Significant differences were found in technical quality ( P <0.001) and diagnostic value ( P <0.001) depending on which system was used, with higher scores for the Viatronix software. The agreement between specialists tended to be higher than that between residents (κ = 0.63 (0.30-0.95) vs. κ = 0.51 (0.21-0.81)), and the residents gave significantly ( P <0.001) higher scores of technical quality. However, the level of expertise had no significant impact on the assessments. We noted extensive variability in pathological lesions found by the different observers. The number of findings did not differ between workstations, but the viewers tended to report larger polyp sizes with the Viatronix software. The time needed for viewing decreased significantly from the first to the last examination viewed by each observer. Conclusion: Both the evaluated systems present trustworthy images of the human colon, but in a primary 3D setting the Viatronix software is favored owing to the userfriendly interface, higher experienced technical quality, and better diagnostic value. © 2005 Taylor & Francis.

Ort, förlag, år, upplaga, sidor
2005. Vol. 46, nr 7, s. 671-678
Nyckelord [en]
Abdomen/GI, computer applications, 3D, computer applications, virtual imaging, CT, spiral
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-30554DOI: 10.1080/02841850500223109Lokalt ID: 16142OAI: oai:DiVA.org:liu-30554DiVA, id: diva2:251377
Tillgänglig från: 2009-10-09 Skapad: 2009-10-09 Senast uppdaterad: 2017-12-13

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Persson, AndersNorén, BengtMalcherek, PerAxelsson, MathiasJohansson, JamesSmedby, Örjan

Sök vidare i DiVA

Av författaren/redaktören
Persson, AndersNorén, BengtMalcherek, PerAxelsson, MathiasJohansson, JamesSmedby, Örjan
Av organisationen
HälsouniversitetetMedicinsk radiologiAvdelningen för radiologi USCentrum för medicinsk bildvetenskap och visualisering, CMIVInstitutionen för medicin och vård
I samma tidskrift
Acta Radiologica
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 237 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf