Interference of 7-hydroxymethotrexate with the determination of methotrexate in plasma samples from children with acute lymphoblastic leukemia employing routine clinical assays
Cancercenter KI, Stockholm.
Lund.
Karolinska.
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Klinisk farmakologi. Östergötlands Läns Landsting, Laboratoriemedicinskt centrum, Klinisk farmakologi.
Vise andre og tillknytning
2005 (engelsk)Inngår i: Journal of chromatography. B, ISSN 1570-0232, E-ISSN 1873-376X, Vol. 817, nr 2, s. 139-144Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The accuracy of two clinical assays, the enzyme-multiplied immunoassay (EMIT) and fluorescence polarization immunoassay (FPIA2), universally employed for measurement of plasma levels of methotrexate (MTX) in children administered a high dose of this drug for treatment of acute lymphoblastic leukemia was evaluated here. Because of its superior specificity, sensitivity, and precision, high performance liquid chromatography (HPLC) was selected as the reference method with which the other two procedures were compared using approximately 420 different plasma samples for method comparison. 7-Hydroxymethotrexate (7-OHMTX), the major plasma metabolite of MTX, that can be detected in plasma at relatively high concentrations for long periods following infusion of a high dose of MTX, was also quantitated by HPLC. Forty-two and 66 h after infusion, the plasma level of MTX was overestimated in 2% and 3% of the samples by the FPIA2 procedure in 5% and 31% by the EMIT assay. The overall correlation coefficients (r2) for the values obtained by FPIA2 or EMIT versus those based on HPLC were 0.989 and 0.663, respectively. The presence of 7-OHMTX exerted a highly significant influence (p = 0.0007 as determined by the unpaired t-test) on MTX measurement by the EMIT assay. We conclude that the rapid automated procedures routinely used at present and in particular EMIT, suffer from cross-reactivity with metabolites of MTX. Thus, the relatively high percentage of samples in which the level of MTX is overestimated at check-points by EMIT may result in longer periods of hospitalization, higher costs and prolonged administration of elevated doses of "rescue" leucovorin with an increased risk for relapse. © 2004 Elsevier B.V. All rights reserved.

sted, utgiver, år, opplag, sider
2005. Vol. 817, nr 2, s. 139-144
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-31693DOI: 10.1016/j.jchromb.2004.11.037Lokal ID: 17511OAI: oai:DiVA.org:liu-31693DiVA, id: diva2:252516
Tilgjengelig fra: 2009-10-09 Laget: 2009-10-09 Sist oppdatert: 2017-12-13

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Peterson, CurtAlbertioni, Freidoun

Søk i DiVA

Av forfatter/redaktør
Peterson, CurtAlbertioni, Freidoun
Av organisasjonen
I samme tidsskrift
Journal of chromatography. B

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 183 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf