liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Higher order weighted least-squares phase offset correction for improved accuracy in phase-contrast MRI
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.ORCID-id: 0000-0003-1395-8296
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
Vise andre og tillknytning
2008 (engelsk)Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Phase-contrast magnetic resonance imaging has the ability to accurately measure blood flow and myocardial velocities in the human body. Unwanted spatially varying phase offsets are, however, always present and may deteriorate the measurements significantly. Some of these phase offsets can be estimated based on the pulse sequence (1), but effects caused by eddy currents are more difficult to predict. A linear fit of the phase values is often estimated from either a number of manually defined areas containing stationary tissue or by semi-automatic detection of stationary tissue using the

sted, utgiver, år, opplag, sider
2008.
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-61147OAI: oai:DiVA.org:liu-61147DiVA, id: diva2:360658
Konferanse
ISMRM
Tilgjengelig fra: 2010-11-09 Laget: 2010-11-04 Sist oppdatert: 2013-09-03bibliografisk kontrollert

Open Access i DiVA

Higer order weighted least-squares phase offset correction for improved accuracy in phase-contrast MRI(67 kB)343 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 67 kBChecksum SHA-512
48ec818c8395a8a87c74ee8b3888be5cc12436436cbef11ef5fe9a131626e5a79b68503b224f6945912809dd6a3a698cef843fcb6eeee6d253a3c5a005a4a226
Type fulltextMimetype application/pdf

Personposter BETA

Ebbers, TinoHaraldsson, HenrikDyverfeldt, PetterSigfridsson, AndreasWarntjes, Marcel Jan BertusWigström, Lars

Søk i DiVA

Av forfatter/redaktør
Ebbers, TinoHaraldsson, HenrikDyverfeldt, PetterSigfridsson, AndreasWarntjes, Marcel Jan BertusWigström, Lars
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 343 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 883 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf