liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Application of adaptive non-linear 2D and 3D postprocessing filters for reduced dose abdominal CT
Drammen and Buskerud University of College.
Harvard University.
Akershus University Hospital.
ContextVision AB.
Visa övriga samt affilieringar
2012 (Engelska)Ingår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 53, nr 3, s. 335-342Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: Abdominal computed tomography (an is a frequently performed imaging procedure, resulting in considerable radiation doses to the patient population. Postprocessing filters are one of several dose reduction measures that might help to reduce radiation doses without loss of image quality. less thanbrgreater than less thanbrgreater thanPurpose: To assess and compare the effect of two- and three-dimensional (2D, 3D) non-linear adaptive filters on reduced dose abdominal CT images. less thanbrgreater than less thanbrgreater thanMaterial and Methods: Two baseline abdominal CT image series with a volume computer tomography dose index (CTDI (vol)) of 12 mGy and 6 mGy were acquired for 12 patients. Reduced dose images were postprocessed with 2D and 3D filters. Six radiologists performed blinded randomized, side-by-side image quality assessments. Objective noise was measured. Data were analyzed using visual grading regression and mixed linear models. less thanbrgreater than less thanbrgreater thanResults: All image quality criteria were rated as superior for 3D filtered images compared to reduced dose baseline and 2D filtered images (P andlt; 0.01). Standard dose images had better image quality than reduced dose 3D filtered images (P andlt; 0.01), but similar image noise. For patients with body mass index (BMI) andlt; 30 kg/m(2) however, 3D filtered images were rated significantly better than normal dose images for two image criteria (P andlt; 0.05), while no significant difference was found for the remaining three image criteria (P andgt; 0.05). There were no significant variations of objective noise between standard dose and 2D or 3D filtered images. less thanbrgreater than less thanbrgreater thanConclusion: The quality of 3D filtered reduced dose abdominal CT images is superior compared to reduced dose unfiltered and 2D filtered images. For patients with BMI andlt; 30 kg/m(2), 3D filtered images are comparable to standard dose images.

Ort, förlag, år, upplaga, sidor
Informa Healthcare / Wiley-Blackwell / Royal Society of Medicine Press , 2012. Vol. 53, nr 3, s. 335-342
Nyckelord [en]
Abdomen/GI, CT, pancreas, adults, computer applications, radiation safety
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-77733DOI: 10.1258/ar.2011.110563ISI: 000303556300017OAI: oai:DiVA.org:liu-77733DiVA, id: diva2:529440
Anmärkning
Funding Agencies|Norwegian Radiological Society||Radiological Society of North America||GE Healthcare||Tillgänglig från: 2012-05-30 Skapad: 2012-05-28 Senast uppdaterad: 2017-12-07

Open Access i DiVA

fulltext(619 kB)946 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 619 kBChecksumma SHA-512
fdfcb3b3865c37c731fde1df887d89b6cfedbf1e5de2a90d7cc7e7b0851bfb6db451fe6ad7bf2ddcf81164c4c2b5bccffa671aacd4b67a33812d3f94b00ff9c8
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Personposter BETA

Sandborg, MichaelSmedby, Örjan

Sök vidare i DiVA

Av författaren/redaktören
Sandborg, MichaelSmedby, Örjan
Av organisationen
Medicinsk radiofysikHälsouniversitetetRadiofysikavdelningen USCentrum för medicinsk bildvetenskap och visualisering, CMIVMedicinsk radiologiRöntgenkliniken i Linköping
I samma tidskrift
Acta Radiologica
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 946 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 434 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf