Four-dimensional flow MRI using spiral acquisition
Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.ORCID-id: 0000-0003-2198-9690
Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.ORCID-id: 0000-0003-1395-8296
2012 (Engelska)Ingår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 68, nr 4, s. 1065-1073Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Time-resolved three-dimensional phase-contrast MRI is an important tool for physiological as well as clinical studies of blood flow in the heart and vessels. The application of the technique is, however, limited by the long scan times required. In this work, we investigate the feasibility of using spiral readouts to reduce the scan time of four-dimensional flow MRI without sacrificing quality. Three spiral approaches are presented and evaluated in vivo and in vitro against a conventional Cartesian acquisition. In vivo, the performance of each method was assessed in the thoracic aorta in 10 volunteers using pathline-based analysis and cardiac output analysis. Signal-to-noise ratio and background phase errors were investigated in vitro. Using spiral readouts, the scan times of a four-dimensional flow acquisition of the thoracic aorta could be reduced 23-fold, with no statistically significant difference in pathline validity or cardiac output. The shortened scan time improves the applicability of four-dimensional flow MRI, which may allow the technique to become a part of a clinical workflow for cardiovascular functional imaging.

Ort, förlag, år, upplaga, sidor
Wiley-Blackwell , 2012. Vol. 68, nr 4, s. 1065-1073
Nyckelord [en]
cine three-dimensional flow, phase contrast, spiral, pathline
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-84888DOI: 10.1002/mrm.23297ISI: 000309203500008OAI: oai:DiVA.org:liu-84888DiVA, id: diva2:564004
Anmärkning

Funding Agencies|Swedish Research Council||Swedish Heart-Lung Foundation||

Tillgänglig från: 2012-11-01 Skapad: 2012-10-26 Senast uppdaterad: 2017-12-07Bibliografiskt granskad
Ingår i avhandling
1. Fast and Accurate 4D Flow MRI for Cardiovascular Blood Flow Assessment
Öppna denna publikation i ny flik eller fönster >>Fast and Accurate 4D Flow MRI for Cardiovascular Blood Flow Assessment
2013 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

The study of blood flow is essential in understanding the physiology and pathophysiology of the cardiovascular system. Small disturbances of the blood flow may over time evolve and contribute to cardiovascular pathology. While the blood flow in a healthy human appears to be predominately laminar, turbulent or transitional blood flow is thought to be involved in the pathogenesis of several cardiovascular diseases. Wall shear stress is the frictional force of blood on the vessel wall and has been linked to the pathogenesis of atherosclerosis and aneurysms. Despite the importance of hemodynamic factors, cardiovascular diagnostics largely relies on the indirect estimation of function based on morphological data.

Time-resolved three-dimensional (3D) phase-contrast magnetic resonance imaging (MRI), often referred to as 4D flow MRI, is a versatile and non-invasive tool for cardiovascular blood flow assessment. The use of 4D flow MRI permits estimation of flow volumes, pressure losses, wall shear stress, turbulence intensity and many other unique hemodynamic parameters. However, 4D flow MRI suffers from long scan times, sometimes over 40 minutes. Furthermore, the accuracy of the many different 4D flow MRI-based applications and estimates have not been thoroughly examined.

In this thesis, the accuracy of 4D flow MRI-based turbulence intensity mapping and wall shear stress estimation was investigated by using numerical simulations of MRI flow measurements. While the results from the turbulence intensity mapping agreed well with reference values from computational fluid dynamics data, the accuracy of the MRI-based wall shear stress estimates was found to be very sensitive to different parameters, especially to spatial resolution, and wall shear stress values over 5 N/m2 were not well resolved.

To reduce the scan time, a 4D flow MRI sequence using spiral k-space trajectories was implemented and validated in-vivo and in-vitro. The scan time of 4D flow MRI was reduced by more than two-fold compared to a conventional Cartesian acquisition already accelerated using SENSE factor 2, and the data quality was maintained. For a 4D flow scan of the human heart, the use of spiral k-space trajectories resulted in a scan time of around 13 min, compared to 30 min for the Cartesian acquisition. By combining parallel imaging and spiral trajectories, the total scan time of a 4D flow measurement of the entire heart may be further reduced. This scan time reduction may also be traded for higher spatial resolution.

Numerical simulation of 4D flow MRI may act as an important tool for future optimization and validation of the spiral 4D flow sequence. The scan-time reductions offered by the spiral k-space trajectories can help to cut costs, save time, reduce discomfort for the patient as well as to decrease the risk for motion artifacts. These benefits may facilitate an expanded clinical and investigative use of 4D flow MRI, including larger patient research studies.

Ort, förlag, år, upplaga, sidor
Linköping: Linköping University Electronic Press, 2013
Serie
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1380
Nationell ämneskategori
Medicinteknik
Identifikatorer
urn:nbn:se:liu:diva-100146 (URN)10.3384/diss.diva-100146 (DOI)978-91-7519-506-3 (ISBN)
Disputation
2013-12-13, Berzeliussalen, Campus Valla, Linköpings universitet, Linköping, 09:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2013-11-07 Skapad: 2013-10-29 Senast uppdaterad: 2019-12-08Bibliografiskt granskad

Open Access i DiVA

fulltext(785 kB)810 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 785 kBChecksumma SHA-512
1d13e224683776deab89daccd5cfe2a45b1db28afb7208cae2cd0846ff6f2b33d5a44fd4a31b328fe6f24b6d54d168554a2c14aad83613821891f3ba7fd67e46
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Personposter BETA

Sigfridsson, AndreasPetersson, SvenCarlhäll, CarljohanEbbers, Tino

Sök vidare i DiVA

Av författaren/redaktören
Sigfridsson, AndreasPetersson, SvenCarlhäll, CarljohanEbbers, Tino
Av organisationen
Klinisk fysiologiHälsouniversitetetFysiologiska kliniken USCentrum för medicinsk bildvetenskap och visualisering, CMIVAvdelningen för kardiovaskulär medicin
I samma tidskrift
Magnetic Resonance in Medicine
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 810 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 257 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf