Sinogram-Affirmed Iterative Reconstruction of Low-Dose Chest CT: Effect on Image Quality and Radiation Dose
Division of Thoraic Imaging, Department of Radiology, Massachusetts General Hospital, Boston, USA .
Linköping University, Center for Medical Image Science and Visualization (CMIV). Linköping University, Department of Medical and Health Sciences, Radiology. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Center for Diagnostics, Department of Radiology in Linköping.
Linköping University, Center for Medical Image Science and Visualization (CMIV). Linköping University, Department of Medical and Health Sciences, Radiology. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Center for Diagnostics, Department of Radiology in Linköping.ORCID iD: 0000-0002-4111-1693
Massachusetts General Hospital, Boston, USA .
Show others and affiliations
2013 (English)In: American Journal of Roentgenology, ISSN 0361-803X, E-ISSN 1546-3141, Vol. 201, no 2, p. W235-W244Article in journal (Refereed) Published
Abstract [en]

OBJECTIVE. The purpose of this study is to compare sinogram-affirmed iterative reconstruction (SAFIRE) and filtered back projection (FBP) reconstruction of chest CT acquired with 65% radiation dose reduction.

SUBJECTS AND METHODS. In this prospective study involving 24 patients (11 women and 13 men; mean [+/- SD] age, 66 +/- 10 years), two scan series were acquired using 100 and 40 Quality Reference mAs over a 10-cm scan length in the chest with a 128-MDCT scanner. The 40 Quality Reference mAs CT projection data were reconstructed with FBP and four settings of Safire (S1, S2, S3, and S4). Six image datasets (FBP with 100 and 40 Quality Reference mAs, and S1, S2, S3, S4 with 40 Quality Reference mAs) were displayed on a DICOM-compliant 55-inch 2-megapixel monitor for blinded evaluation by two thoracic radiologists for number and location of lesions, lesion size, lesion margins, visibility of small structures and fissures, and diagnostic confidence. Objective noise and CT values were measured in thoracic aorta for each image series, and the noise power spectrum was assessed. Data were analyzed with analysis of variance and Wilcoxon signed rank tests.

RESULTS. All 186 lesions were seen on 40 Quality Reference mAs SAFIRE images. Diagnostic confidence on SAFIRE images was higher than that for FBP images. Except for the minor blotchy appearance on SAFIRE settings S3 and S4, no significant artifacts were noted. Objective noise with 40 Quality Reference mAs S1 images (21.1 +/- 6.1 SD of HU) was significantly lower than that for 40 Quality Reference mAs FBP images (28.5 +/- 8.1 SD of HU) (p andlt; 0.001). Noise power spectra were identical for SAFIRE and FBP with progressive noise reduction with higher iteration SAFIRE settings.

CONCLUSION. Iterative reconstruction (SAFIRE) allows reducing the radiation exposure by approximately 65% without losing diagnostic information in chest CT.

Place, publisher, year, edition, pages
American Roentgen Ray Society (ARRS) , 2013. Vol. 201, no 2, p. W235-W244
Keywords [en]
iterative reconstruction, low-dose chest CT, radiation dose reduction
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-96707DOI: 10.2214/AJR.12.9569ISI: 000322225400008OAI: oai:DiVA.org:liu-96707DiVA, id: diva2:642974
Note

Funding Agencies|Siemens Healthcare||

Available from: 2013-08-23 Created: 2013-08-23 Last updated: 2017-12-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Woisetschläger, MischaDahlström, NilsQuick, PetterPersson, Anders

Search in DiVA

By author/editor
Woisetschläger, MischaDahlström, NilsQuick, PetterPersson, Anders
By organisation
Center for Medical Image Science and Visualization (CMIV)RadiologyFaculty of Health SciencesDepartment of Radiology in Linköping
In the same journal
American Journal of Roentgenology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 203 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf